ELGIP-91 - Changed the polarity of the new triggers for in-line merge synchronization

This commit is contained in:
gianmarcogirau 2020-05-18 14:01:10 +01:00
commit 485188f6b0

View file

@ -6,7 +6,7 @@
-- Author : Gianmarco Girau
-- Company : Global Inkjet Systems
-- Created : 2016-10-24
-- Last update: 2020-05-15
-- Last update: 2020-05-18
-- SVN ID : Git
-- Standard : VHDL'93
-------------------------------------------------------------------------------
@ -363,7 +363,7 @@ begin
bus_valid => seq_bus_valid,
bus_ack => '1');
ch_ctrl_trigger_in <= (0 => loc_pd, 1 => fire_enable, 2 => gated_pulse, 3 => (not fire_enable), 4 => stream_busy_a, 5 => stream_busy_b);
ch_ctrl_trigger_in <= (0 => loc_pd, 1 => fire_enable, 2 => gated_pulse, 3 => (not fire_enable), 4 => (not stream_busy_a), 5 => (not stream_busy_b));
ch_mask_i <= fire_enable or ch_ctrl_vector_out(1) or bypass_ch_ctrl;