From ae26e0c6c69eecd4f94464fff8a8759bf4e22c97 Mon Sep 17 00:00:00 2001 From: gianmarcogirau Date: Fri, 17 May 2019 10:51:40 +0100 Subject: [PATCH] ELGIP-45 Added a Pragma to signal out-of-bound trigger selection --- generic_ip/generic_sequencer/15/src/generic_sequencer_15.vhd | 4 ++++ 1 file changed, 4 insertions(+) diff --git a/generic_ip/generic_sequencer/15/src/generic_sequencer_15.vhd b/generic_ip/generic_sequencer/15/src/generic_sequencer_15.vhd index 93c8597..a46146a 100644 --- a/generic_ip/generic_sequencer/15/src/generic_sequencer_15.vhd +++ b/generic_ip/generic_sequencer/15/src/generic_sequencer_15.vhd @@ -285,6 +285,10 @@ begin trig_int <= trigger_in(to_integer(unsigned(trig_sel))) and trig_mask(to_integer(unsigned(trig_sel))); + --pragma translate_off + assert (to_integer(unsigned(trig_sel)) < TRIGGER_WIDTH) report "ERROR: trig_sel out of selectable trigger mask" severity failure; + --pragma translate_off + ----------------------------------------------------------------------------- -- Dual-Port Memory buffer -----------------------------------------------------------------------------