ELGIP-143
Update Generic IP JSON "Notes" fields to point to pages in new Cloudy Confluence
This commit is contained in:
parent
ef79fde4fa
commit
f2b1849270
9 changed files with 423 additions and 423 deletions
|
|
@ -3,7 +3,7 @@
|
|||
"bus" : "csr",
|
||||
"addr_width" : "4",
|
||||
"description" : "This block is the generic delay queue",
|
||||
"notes" : "This is the generic delay queue component, used in various projects. Details of this block can be found at https://confluence.gisapps.co.uk/display/EL/Generic+Delay+Queue.",
|
||||
"notes" : "This is the generic delay queue component, used in various projects. Details of this block can be found at https://congis.atlassian.net/wiki/spaces/EL/pages/26770442231/Generic+Delay+Queue",
|
||||
"registers" : {
|
||||
"ip_id" : {
|
||||
"address" : "0",
|
||||
|
|
@ -107,4 +107,4 @@
|
|||
"description" : "Sets the CPU ingress data and packet delay (when in CPU mode). As the widths of these are dependent on generics, and occupy consecutive bits, the field widths are undefined, except that the ingress data is the first DATA_WIDTH bits and the packet delay is the next DELAY_WIDTH bits, as defined in the CONFIG register"
|
||||
}
|
||||
}
|
||||
}]
|
||||
}]
|
||||
|
|
|
|||
|
|
@ -3,7 +3,7 @@
|
|||
"bus" : "csr",
|
||||
"addr_width" : "6",
|
||||
"description" : "This block is the generic PIO",
|
||||
"notes" : "This is a generic Programmed Input/Output component used in various products. More details can be found at https://confluence.gisapps.co.uk/display/EL/Generic+PIO.",
|
||||
"notes" : "This is a generic Programmed Input/Output component used in various products. More details can be found at https://congis.atlassian.net/wiki/spaces/EL/pages/26770442233/Generic+PIO",
|
||||
"registers" : {
|
||||
"ip_id" : {
|
||||
"address" : "0",
|
||||
|
|
|
|||
|
|
@ -3,7 +3,7 @@
|
|||
"bus" : "csr",
|
||||
"addr_width" : "4",
|
||||
"description" : "This block is the multi alter 1MBaud UART interface for alerts",
|
||||
"notes" : "The Multi-alert UART receiver is a generic component, used in multiple projects, which receives messages over multiple UART receivers (at 1MBaud), configurable up to 16 channels, indicating under-range and over-range alerts from STM8 devices and generating trigger outputs for a shutdown monitor (see https://confluence.gisapps.co.uk/pages/viewpage.action?spaceKey=DHBTTCF3&title=CF3+Logic+Design#CF3LogicDesign-ShutdownMonitor). More details of an example deployment of this block, and its use, can be found at https://confluence.gisapps.co.uk/pages/viewpage.action?spaceKey=DHBTTCF3&title=CF3+Logic+Design#CF3LogicDesign-Stm8AlertUartSTM8AlertReceiver).",
|
||||
"notes" : "The Multi-alert UART receiver is a generic component, used in multiple projects, which receives messages over multiple UART receivers (at 1MBaud), configurable up to 16 channels, indicating under-range and over-range alerts from STM8 devices and generating trigger outputs for a shutdown monitor (see https://confluence.gisapps.co.uk/pages/viewpage.action?spaceKey=DHBTTCF3&title=CF3+Logic+Design#CF3LogicDesign-ShutdownMonitor). More details of an example deployment of this block, and its use, can be found at https://congis.atlassian.net/wiki/spaces/DHBTTCF3/pages/138292168371/CF3+Logic+Design#CF3LogicDesign-Stm8AlertUartSTM8AlertReceiver).",
|
||||
"registers" : {
|
||||
"ip_id" : {
|
||||
"address" : "0",
|
||||
|
|
@ -21,7 +21,7 @@
|
|||
"bit_len" : "8",
|
||||
"reset" : "0xFF",
|
||||
"description" : "Manufacturer number"
|
||||
|
||||
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
|
|
@ -46,7 +46,7 @@
|
|||
"bit_len" : "8",
|
||||
"reset" : "0x00",
|
||||
"description" : "Major number"
|
||||
|
||||
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
|
|
@ -103,7 +103,7 @@
|
|||
"reset" : "0",
|
||||
"description" : "Last ordninal received"
|
||||
}
|
||||
|
||||
|
||||
}
|
||||
},
|
||||
"clr_alert" : {
|
||||
|
|
@ -114,4 +114,4 @@
|
|||
"description" : "Writing 1 to this register clears any alert status."
|
||||
}
|
||||
}
|
||||
}]
|
||||
}]
|
||||
|
|
|
|||
|
|
@ -3,7 +3,7 @@
|
|||
"bus" : "csr",
|
||||
"addr_width" : "4",
|
||||
"description" : "This block is the print streamer for the GMA SOM board soft IP",
|
||||
"notes" : "The print streamer is a block that allows read access to the main memory. It is either used to access physical locations in memory, or to access virtual locations mapped to physical page blocks (4096 bytes, or 1024 words). The main CPU control is via the CMD_PORT register. This accepts a variety of commands (see https://confluence.gisapps.co.uk/display/EL/Embedded+Logic+Print+Streamer+New+Architecture) to send stripe data to external ports, to put virtual to physical mappings into the TLB queue or to load new commands directly into the command queue from memory. The CPU must only send commands (two words) when there is sufficient space, as indicated by the QUEUE_SPACE field of the STATUS register. When using the RD_STRIPE_PADDR command, the TLB queue can be empty (with no LOAD_ADDR_MAP commands needed). When using one of the virtual address commands (e.g. RD_STRIPE_VADDR or LOAD_CMD_Q), the TLB queue must be pre-filled with mappings that cover the data transfer commands, using the LD_ADDR_MAP command. If the transfer is less than a page length, and does not cross a page boundary, then a LD_ADDR_MAP command is sent to map the physical location to the virtual address of the data, before sending the RD_STRIPE_VADDR command. If the data spans a page boundary, then two LD_ADDR_MAP commands are sent prior to the RD_STRIPE_VADDR, to map the two separate physical pages to the two (contiguous) pages in the virtual address space. Similarly, if a transfer spans multiple pages, the appropriate number of LD_ADDR_MAP commands are sent first before the RD_STRIPE_VADDR command to cover the pages for that data. Note that if the transfer is a continuation of data in a page that the last transfer completed in, then the map for this first page should not be sent, as it will still be the active mapping in the streamer. The CLR_CMD bit in the CONTROL register clears all commands and TLB mappings, so for a completely new transfer the TLB can be reset with this. The print streamer is capable of loading itself with new commands directly from memory, also using virtual addressing. The LOAD_CMD_Q command is identical in its usage to the RD_STRIPE_VADDR command, but with the destination being the command queue. Therefore commands can be pre-compiled in memory and then a LD_CMD_Q command sent to place them in the queue and start executing. If the last command in the batch is also a LD_CMD_Q, then the commands can be linked in memory indefinitely. The print streamer monitors when LD_CMD_Q commands are in the print streamer---either in the command queue itself, or active on the bus. This status is flagged as the AUTO_CMD_ACTIVE bit of the STATUS register, and the CPU must not attempt to write to the command queue when set, as this is a race hazard and could corrupt the command queue data. If a CPU write does occur, an error is flagged. In addition, if a LD_CMD_Q has a word length that is greater than the command queue length, this is an error and flagged. Various errors are monitored for, and the STATUS register returns various error statuses. If any error is active, then the print streamer is halted until the error consitions are cleared via the CLEAR_ERRORS and CLEAR_CMD bits of the CONTROL register. The errors detected include a failure to get a TLB virtual/physical mapping, an empty TLB queue when processing a virtual address command, an LD_CMD_Q with a too large word length parameter, an unrecognised command and a CPU access when LD_CMD_Q active (see the error bits of the STATUS register). The print streamer can generate an interrupt to the CPU. All error types will assert the IRQ output. In addition, if the number of commands in the command queue falls below a certain value, as configured in the WATERMARK field of the CONTROL register, IRQ is also asserted. This is effectively disabled if the watermark value is 0 (the reset value).",
|
||||
"notes" : "The print streamer is a block that allows read access to the main memory. It is either used to access physical locations in memory, or to access virtual locations mapped to physical page blocks (4096 bytes, or 1024 words). The main CPU control is via the CMD_PORT register. This accepts a variety of commands (see https://congis.atlassian.net/wiki/spaces/EL/pages/26731086975/Embedded+Logic+Data+Streamer+New+Architecture) to send stripe data to external ports, to put virtual to physical mappings into the TLB queue or to load new commands directly into the command queue from memory. The CPU must only send commands (two words) when there is sufficient space, as indicated by the QUEUE_SPACE field of the STATUS register. When using the RD_STRIPE_PADDR command, the TLB queue can be empty (with no LOAD_ADDR_MAP commands needed). When using one of the virtual address commands (e.g. RD_STRIPE_VADDR or LOAD_CMD_Q), the TLB queue must be pre-filled with mappings that cover the data transfer commands, using the LD_ADDR_MAP command. If the transfer is less than a page length, and does not cross a page boundary, then a LD_ADDR_MAP command is sent to map the physical location to the virtual address of the data, before sending the RD_STRIPE_VADDR command. If the data spans a page boundary, then two LD_ADDR_MAP commands are sent prior to the RD_STRIPE_VADDR, to map the two separate physical pages to the two (contiguous) pages in the virtual address space. Similarly, if a transfer spans multiple pages, the appropriate number of LD_ADDR_MAP commands are sent first before the RD_STRIPE_VADDR command to cover the pages for that data. Note that if the transfer is a continuation of data in a page that the last transfer completed in, then the map for this first page should not be sent, as it will still be the active mapping in the streamer. The CLR_CMD bit in the CONTROL register clears all commands and TLB mappings, so for a completely new transfer the TLB can be reset with this. The print streamer is capable of loading itself with new commands directly from memory, also using virtual addressing. The LOAD_CMD_Q command is identical in its usage to the RD_STRIPE_VADDR command, but with the destination being the command queue. Therefore commands can be pre-compiled in memory and then a LD_CMD_Q command sent to place them in the queue and start executing. If the last command in the batch is also a LD_CMD_Q, then the commands can be linked in memory indefinitely. The print streamer monitors when LD_CMD_Q commands are in the print streamer---either in the command queue itself, or active on the bus. This status is flagged as the AUTO_CMD_ACTIVE bit of the STATUS register, and the CPU must not attempt to write to the command queue when set, as this is a race hazard and could corrupt the command queue data. If a CPU write does occur, an error is flagged. In addition, if a LD_CMD_Q has a word length that is greater than the command queue length, this is an error and flagged. Various errors are monitored for, and the STATUS register returns various error statuses. If any error is active, then the print streamer is halted until the error consitions are cleared via the CLEAR_ERRORS and CLEAR_CMD bits of the CONTROL register. The errors detected include a failure to get a TLB virtual/physical mapping, an empty TLB queue when processing a virtual address command, an LD_CMD_Q with a too large word length parameter, an unrecognised command and a CPU access when LD_CMD_Q active (see the error bits of the STATUS register). The print streamer can generate an interrupt to the CPU. All error types will assert the IRQ output. In addition, if the number of commands in the command queue falls below a certain value, as configured in the WATERMARK field of the CONTROL register, IRQ is also asserted. This is effectively disabled if the watermark value is 0 (the reset value).",
|
||||
"registers" : {
|
||||
"ip_id" : {
|
||||
"address" : "0",
|
||||
|
|
|
|||
|
|
@ -3,7 +3,7 @@
|
|||
"bus" : "csr",
|
||||
"addr_hi_bit" : "6",
|
||||
"addr_lo_bit" : "4",
|
||||
"description" : "This block is the print streamer for the Presto products. It is a collection of data streamers (see https://confluence.gisapps.co.uk/display/EL/Embedded+Logic+Data+Streamer+New+Architecture) and support logic for multiple heads. More details can be found at https://confluence.gisapps.co.uk/display/EL/Print+Streamer.",
|
||||
"description" : "This block is the print streamer for the Presto products. It is a collection of data streamers (see https://congis.atlassian.net/wiki/spaces/EL/pages/26731086975/Embedded+Logic+Data+Streamer+New+Architecture) and support logic for multiple heads. More details can be found at https://confluence.gisapps.co.uk/display/EL/Print+Streamer.",
|
||||
"sub_blocks" : {
|
||||
"data_streamer_8:a" : {
|
||||
"instance" : "0",
|
||||
|
|
|
|||
|
|
@ -3,7 +3,7 @@
|
|||
"bus" : "csr",
|
||||
"addr_width" : "6",
|
||||
"description" : "This block is the emergency shutdown monitor for HMB-FD-HV",
|
||||
"notes" : "The shutdown monitor is used in various products to facilitate the powering up and down of power supplies, and the monitoring of critical signals and alerts in order to shutdown the supplies in the case of a failure mode. More details of the shutdown monitor, and its use, can be found at https://confluence.gisapps.co.uk/display/EL/Shutdown+Monitor .",
|
||||
"notes" : "The shutdown monitor is used in various products to facilitate the powering up and down of power supplies, and the monitoring of critical signals and alerts in order to shutdown the supplies in the case of a failure mode. More details of the shutdown monitor, and its use, can be found at https://congis.atlassian.net/wiki/spaces/EL/pages/26770443999/Shutdown+Monitor .",
|
||||
"registers" : {
|
||||
"ip_id" : {
|
||||
"address" : "0",
|
||||
|
|
@ -21,7 +21,7 @@
|
|||
"bit_len" : "8",
|
||||
"reset" : "0x00",
|
||||
"description" : "Manufacturer number"
|
||||
|
||||
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
|
|
@ -46,7 +46,7 @@
|
|||
"bit_len" : "8",
|
||||
"reset" : "0x00",
|
||||
"description" : "Major number"
|
||||
|
||||
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
|
|
@ -320,4 +320,4 @@
|
|||
"description" : "Shutdown delay, in system clock cycles (nominally 10ns), from shutdown event for signal 18."
|
||||
}
|
||||
}
|
||||
}]
|
||||
}]
|
||||
|
|
|
|||
|
|
@ -1,423 +1,423 @@
|
|||
[{
|
||||
"ip_name" : "signal_sequencer_10",
|
||||
"bus" : "csr",
|
||||
"addr_hi_bit" : "9",
|
||||
"addr_lo_bit" : "4",
|
||||
"description" : "Generic Signal-Sequencer",
|
||||
"notes" : "The component is a signal sequencer used to generate a variety of control signals, programmably. It used the generic sequencer at its core (see https://confluence.gisapps.co.uk/display/EL/Generic+Sequencer). More details of this component can be found at https://confluence.gisapps.co.uk/display/EL/Generic+Sequencer.",
|
||||
"sub_blocks" : {
|
||||
"generic_sequencer_15" : {
|
||||
"instance" : "",
|
||||
"process" : "enabled",
|
||||
"offset" : "0x10"
|
||||
},
|
||||
"local" : {
|
||||
"instance" : "",
|
||||
"process" : "enabled",
|
||||
"offset" : "0x00"
|
||||
}
|
||||
},
|
||||
"registers" : {
|
||||
"ip_id" : {
|
||||
"address" : "0x0",
|
||||
"width" : "32",
|
||||
"description" : "Unique ID for this IP block",
|
||||
"fields": {
|
||||
"ip_number" : {
|
||||
"type" : "c",
|
||||
"bit_len" : "8",
|
||||
"reset" : "0x06",
|
||||
"description" : "IP identifier number"
|
||||
},
|
||||
"mfr_number" : {
|
||||
"type" : "c",
|
||||
"bit_len" : "8",
|
||||
"reset" : "0xFF",
|
||||
"description" : "Manufacturer number"
|
||||
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "16",
|
||||
"description" : "Reserved bits"
|
||||
}
|
||||
}
|
||||
},
|
||||
"ip_ver" : {
|
||||
"address" : "0x1",
|
||||
"width" : "32",
|
||||
"description" : "Bits[7:0] = Minor version number, Bits[15:8] = Major version number, etc.",
|
||||
"fields": {
|
||||
"minor_number" : {
|
||||
"type" : "c",
|
||||
"bit_len" : "8",
|
||||
"reset" : "0x0A",
|
||||
"description" : "Minor number"
|
||||
},
|
||||
"major_number" : {
|
||||
"type" : "c",
|
||||
"bit_len" : "8",
|
||||
"reset" : "0x00",
|
||||
"description" : "Major number"
|
||||
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "16",
|
||||
"description" : "Reserved bits"
|
||||
}
|
||||
}
|
||||
},
|
||||
"status" : {
|
||||
"address" : "0x2",
|
||||
"width" : "32",
|
||||
"description" : "Status register (sort of)",
|
||||
"fields" : {
|
||||
"good_filt" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x00",
|
||||
"description" : "When written sets CPU status value. When read reads status_good_filt"
|
||||
},
|
||||
"power_status" : {
|
||||
"type" : "r",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Power-Status (1 => Power-Up completed, 0 => Power is not up)."
|
||||
},
|
||||
"shutdn_done" : {
|
||||
"type" : "r",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Shut-down done: asserted upon the completion of an emergency shut-down."
|
||||
},
|
||||
"enable_status" : {
|
||||
"type" : "r",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Enable status: reports whether Signal-Sequencer is enabled"
|
||||
},
|
||||
"enable_wd_alarm" : {
|
||||
"type" : "r",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Enable-Watchdog alarm: asserted after the enable-watchdog is triggered"
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "10",
|
||||
"description" : "Reserved bits"
|
||||
},
|
||||
"busy" : {
|
||||
"type" : "r",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Seq-Core Busy status."
|
||||
},
|
||||
"mode" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Status CPU Mode (1 => Status bits are SW driven). When 1, SW drives the 'status_good' inputs from this register (and they are inverted to drive the 'status_bad' signals."
|
||||
}
|
||||
}
|
||||
},
|
||||
"control" : {
|
||||
"address" : "0x3",
|
||||
"width" : "32",
|
||||
"description" : "Control register",
|
||||
"fields" : {
|
||||
"cpu" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x0000",
|
||||
"description" : "CPU control value"
|
||||
},
|
||||
"enable_req" : {
|
||||
"type" : "wp",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Enable Request (Self-Clearing)"
|
||||
},
|
||||
"disable_req" : {
|
||||
"type" : "wp",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Disable Request (Self-Clearing)"
|
||||
},
|
||||
"clr_en_wd" : {
|
||||
"type" : "wp",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Clears the Enable-Watchdog (Self-Clearing)"
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "1",
|
||||
"description" : "Reserved bits"
|
||||
},
|
||||
"enable_wd_period" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "6",
|
||||
"reset" : "0x0A",
|
||||
"description" : "Enable-Watchdog period [100 ms]"
|
||||
},
|
||||
"reserved (2)" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "5",
|
||||
"description" : "Reserved bits"
|
||||
},
|
||||
"mode" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "CPU control mode: 0 => Control outputs are driven by the Sequencer, 1 => Control outputs are driven by the SW"
|
||||
}
|
||||
}
|
||||
},
|
||||
"latched" : {
|
||||
"address" : "0x4",
|
||||
"width" : "32",
|
||||
"description" : "Status latched",
|
||||
"fields" : {
|
||||
"good" : {
|
||||
"type" : "rwp",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x0000",
|
||||
"description" : "Status good latched: latches the status until a read access"
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "14",
|
||||
"description" : "Reserved bits"
|
||||
},
|
||||
"busy" : {
|
||||
"type" : "rwp",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Busy status latched: latches sequencer-busy status until a read access"
|
||||
},
|
||||
"reserved (2)" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "1",
|
||||
"description" : "Reserved bits"
|
||||
}
|
||||
}
|
||||
},
|
||||
"pwr_up_start" : {
|
||||
"address" : "0x5",
|
||||
"width" : "8",
|
||||
"type" : "wp",
|
||||
"reset" : "0x0",
|
||||
"description" : "Sequence power-up address. A power-up request is automatically issued when writing to this register."
|
||||
},
|
||||
"pwr_dn_start" : {
|
||||
"address" : "0x6",
|
||||
"width" : "8",
|
||||
"type" : "wp",
|
||||
"reset" : "0",
|
||||
"description" : "Sequence power-down address. A power-down request is automatically issued when writing to this register."
|
||||
},
|
||||
"irq_mask" : {
|
||||
"address" : "0x7",
|
||||
"width" : "16",
|
||||
"type" : "w",
|
||||
"reset" : "0",
|
||||
"description" : "Interrupt request mask"
|
||||
},
|
||||
"irq_status" : {
|
||||
"address" : "0x8",
|
||||
"width" : "16",
|
||||
"type" : "rwp",
|
||||
"reset" : "0",
|
||||
"description" : "Interrupt request status. Updates CPU IRQ status when written. Provides (and clears) the past IRQ status when read"
|
||||
},
|
||||
"shutdn_ctrl" : {
|
||||
"address" : "0x9",
|
||||
"width" : "32",
|
||||
"description" : "Shutdown mask",
|
||||
"fields" : {
|
||||
"shutdn_addr" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "8",
|
||||
"reset" : "0x00",
|
||||
"description" : "Shutdown address"
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "8",
|
||||
"description" : "Reserved bits"
|
||||
},
|
||||
"shutdn_mask" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x0000",
|
||||
"description" : "Shutdown mask"
|
||||
}
|
||||
}
|
||||
},
|
||||
"status_invert" : {
|
||||
"address" : "0xA",
|
||||
"width" : "16",
|
||||
"type" : "w",
|
||||
"reset" : "0",
|
||||
"description" : "Status invert"
|
||||
},
|
||||
"chain_len" : {
|
||||
"address" : "0xB",
|
||||
"width" : "32",
|
||||
"description" : "Chain length",
|
||||
"fields" : {
|
||||
"value" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x0000",
|
||||
"description" : "Adjusts how many consecutive cycles a signal must be active before it is accepted through the filter. "
|
||||
},
|
||||
"ip_name" : "signal_sequencer_10",
|
||||
"bus" : "csr",
|
||||
"addr_hi_bit" : "9",
|
||||
"addr_lo_bit" : "4",
|
||||
"description" : "Generic Signal-Sequencer",
|
||||
"notes" : "The component is a signal sequencer used to generate a variety of control signals, programmably. It used the generic sequencer at its core (see https://congis.atlassian.net/wiki/spaces/EL/pages/26730168714/Generic+Sequencer). More details of this component can be found at https://confluence.gisapps.co.uk/display/EL/Generic+Sequencer.",
|
||||
"sub_blocks" : {
|
||||
"generic_sequencer_15" : {
|
||||
"instance" : "",
|
||||
"process" : "enabled",
|
||||
"offset" : "0x10"
|
||||
},
|
||||
"local" : {
|
||||
"instance" : "",
|
||||
"process" : "enabled",
|
||||
"offset" : "0x00"
|
||||
}
|
||||
},
|
||||
"registers" : {
|
||||
"ip_id" : {
|
||||
"address" : "0x0",
|
||||
"width" : "32",
|
||||
"description" : "Unique ID for this IP block",
|
||||
"fields": {
|
||||
"ip_number" : {
|
||||
"type" : "c",
|
||||
"bit_len" : "8",
|
||||
"reset" : "0x06",
|
||||
"description" : "IP identifier number"
|
||||
},
|
||||
"mfr_number" : {
|
||||
"type" : "c",
|
||||
"bit_len" : "8",
|
||||
"reset" : "0xFF",
|
||||
"description" : "Manufacturer number"
|
||||
|
||||
"update" : {
|
||||
"type" : "wp",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x0000",
|
||||
"description" : "Chain length update: i-th bit is asserted to update chain-length for i-th element (Self-Clearing)."
|
||||
}
|
||||
}
|
||||
},
|
||||
"good_bad_stat" : {
|
||||
"address" : "0xC",
|
||||
"width" : "32",
|
||||
"description" : "Combined filtered good/bad status",
|
||||
"fields" : {
|
||||
"good_filt" : {
|
||||
"type" : "rp",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x00",
|
||||
"description" : "Status good filtered"
|
||||
},
|
||||
"bad_filt" : {
|
||||
"type" : "rp",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x00",
|
||||
"description" : "Status bad filtered"
|
||||
}
|
||||
}
|
||||
},
|
||||
"shutdn_rep_reg" : {
|
||||
"address" : "0xD",
|
||||
"width" : "32",
|
||||
"description" : "Shutdown report",
|
||||
"fields" : {
|
||||
"shutdn_cnt" : {
|
||||
"type" : "r",
|
||||
"bit_len" : "8",
|
||||
"reset" : "0x00",
|
||||
"description" : "Shutdown count"
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "7",
|
||||
"description" : "Reserved bits"
|
||||
},
|
||||
"rst_shutdn_cnt" : {
|
||||
"type" : "wp",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Reset the shutdown count"
|
||||
},
|
||||
"shutdn_reason" : {
|
||||
"type" : "r",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x0000",
|
||||
"description" : "Shutdown reason"
|
||||
}
|
||||
}
|
||||
},
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "16",
|
||||
"description" : "Reserved bits"
|
||||
}
|
||||
}
|
||||
},
|
||||
"ip_ver" : {
|
||||
"address" : "0x1",
|
||||
"width" : "32",
|
||||
"description" : "Bits[7:0] = Minor version number, Bits[15:8] = Major version number, etc.",
|
||||
"fields": {
|
||||
"minor_number" : {
|
||||
"type" : "c",
|
||||
"bit_len" : "8",
|
||||
"reset" : "0x0A",
|
||||
"description" : "Minor number"
|
||||
},
|
||||
"major_number" : {
|
||||
"type" : "c",
|
||||
"bit_len" : "8",
|
||||
"reset" : "0x00",
|
||||
"description" : "Major number"
|
||||
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "16",
|
||||
"description" : "Reserved bits"
|
||||
}
|
||||
}
|
||||
},
|
||||
"status" : {
|
||||
"address" : "0x2",
|
||||
"width" : "32",
|
||||
"description" : "Status register (sort of)",
|
||||
"fields" : {
|
||||
"good_filt" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x00",
|
||||
"description" : "When written sets CPU status value. When read reads status_good_filt"
|
||||
},
|
||||
"power_status" : {
|
||||
"type" : "r",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Power-Status (1 => Power-Up completed, 0 => Power is not up)."
|
||||
},
|
||||
"shutdn_done" : {
|
||||
"type" : "r",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Shut-down done: asserted upon the completion of an emergency shut-down."
|
||||
},
|
||||
"enable_status" : {
|
||||
"type" : "r",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Enable status: reports whether Signal-Sequencer is enabled"
|
||||
},
|
||||
"enable_wd_alarm" : {
|
||||
"type" : "r",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Enable-Watchdog alarm: asserted after the enable-watchdog is triggered"
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "10",
|
||||
"description" : "Reserved bits"
|
||||
},
|
||||
"busy" : {
|
||||
"type" : "r",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Seq-Core Busy status."
|
||||
},
|
||||
"mode" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Status CPU Mode (1 => Status bits are SW driven). When 1, SW drives the 'status_good' inputs from this register (and they are inverted to drive the 'status_bad' signals."
|
||||
}
|
||||
}
|
||||
},
|
||||
"control" : {
|
||||
"address" : "0x3",
|
||||
"width" : "32",
|
||||
"description" : "Control register",
|
||||
"fields" : {
|
||||
"cpu" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x0000",
|
||||
"description" : "CPU control value"
|
||||
},
|
||||
"enable_req" : {
|
||||
"type" : "wp",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Enable Request (Self-Clearing)"
|
||||
},
|
||||
"disable_req" : {
|
||||
"type" : "wp",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Disable Request (Self-Clearing)"
|
||||
},
|
||||
"clr_en_wd" : {
|
||||
"type" : "wp",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Clears the Enable-Watchdog (Self-Clearing)"
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "1",
|
||||
"description" : "Reserved bits"
|
||||
},
|
||||
"enable_wd_period" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "6",
|
||||
"reset" : "0x0A",
|
||||
"description" : "Enable-Watchdog period [100 ms]"
|
||||
},
|
||||
"reserved (2)" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "5",
|
||||
"description" : "Reserved bits"
|
||||
},
|
||||
"mode" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "CPU control mode: 0 => Control outputs are driven by the Sequencer, 1 => Control outputs are driven by the SW"
|
||||
}
|
||||
}
|
||||
},
|
||||
"latched" : {
|
||||
"address" : "0x4",
|
||||
"width" : "32",
|
||||
"description" : "Status latched",
|
||||
"fields" : {
|
||||
"good" : {
|
||||
"type" : "rwp",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x0000",
|
||||
"description" : "Status good latched: latches the status until a read access"
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "14",
|
||||
"description" : "Reserved bits"
|
||||
},
|
||||
"busy" : {
|
||||
"type" : "rwp",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Busy status latched: latches sequencer-busy status until a read access"
|
||||
},
|
||||
"reserved (2)" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "1",
|
||||
"description" : "Reserved bits"
|
||||
}
|
||||
}
|
||||
},
|
||||
"pwr_up_start" : {
|
||||
"address" : "0x5",
|
||||
"width" : "8",
|
||||
"type" : "wp",
|
||||
"reset" : "0x0",
|
||||
"description" : "Sequence power-up address. A power-up request is automatically issued when writing to this register."
|
||||
},
|
||||
"pwr_dn_start" : {
|
||||
"address" : "0x6",
|
||||
"width" : "8",
|
||||
"type" : "wp",
|
||||
"reset" : "0",
|
||||
"description" : "Sequence power-down address. A power-down request is automatically issued when writing to this register."
|
||||
},
|
||||
"irq_mask" : {
|
||||
"address" : "0x7",
|
||||
"width" : "16",
|
||||
"type" : "w",
|
||||
"reset" : "0",
|
||||
"description" : "Interrupt request mask"
|
||||
},
|
||||
"irq_status" : {
|
||||
"address" : "0x8",
|
||||
"width" : "16",
|
||||
"type" : "rwp",
|
||||
"reset" : "0",
|
||||
"description" : "Interrupt request status. Updates CPU IRQ status when written. Provides (and clears) the past IRQ status when read"
|
||||
},
|
||||
"shutdn_ctrl" : {
|
||||
"address" : "0x9",
|
||||
"width" : "32",
|
||||
"description" : "Shutdown mask",
|
||||
"fields" : {
|
||||
"shutdn_addr" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "8",
|
||||
"reset" : "0x00",
|
||||
"description" : "Shutdown address"
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "8",
|
||||
"description" : "Reserved bits"
|
||||
},
|
||||
"shutdn_mask" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x0000",
|
||||
"description" : "Shutdown mask"
|
||||
}
|
||||
}
|
||||
},
|
||||
"status_invert" : {
|
||||
"address" : "0xA",
|
||||
"width" : "16",
|
||||
"type" : "w",
|
||||
"reset" : "0",
|
||||
"description" : "Status invert"
|
||||
},
|
||||
"chain_len" : {
|
||||
"address" : "0xB",
|
||||
"width" : "32",
|
||||
"description" : "Chain length",
|
||||
"fields" : {
|
||||
"value" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x0000",
|
||||
"description" : "Adjusts how many consecutive cycles a signal must be active before it is accepted through the filter. "
|
||||
},
|
||||
|
||||
"update" : {
|
||||
"type" : "wp",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x0000",
|
||||
"description" : "Chain length update: i-th bit is asserted to update chain-length for i-th element (Self-Clearing)."
|
||||
}
|
||||
}
|
||||
},
|
||||
"good_bad_stat" : {
|
||||
"address" : "0xC",
|
||||
"width" : "32",
|
||||
"description" : "Combined filtered good/bad status",
|
||||
"fields" : {
|
||||
"good_filt" : {
|
||||
"type" : "rp",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x00",
|
||||
"description" : "Status good filtered"
|
||||
},
|
||||
"bad_filt" : {
|
||||
"type" : "rp",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x00",
|
||||
"description" : "Status bad filtered"
|
||||
}
|
||||
}
|
||||
},
|
||||
"shutdn_rep_reg" : {
|
||||
"address" : "0xD",
|
||||
"width" : "32",
|
||||
"description" : "Shutdown report",
|
||||
"fields" : {
|
||||
"shutdn_cnt" : {
|
||||
"type" : "r",
|
||||
"bit_len" : "8",
|
||||
"reset" : "0x00",
|
||||
"description" : "Shutdown count"
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "7",
|
||||
"description" : "Reserved bits"
|
||||
},
|
||||
"rst_shutdn_cnt" : {
|
||||
"type" : "wp",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Reset the shutdown count"
|
||||
},
|
||||
"shutdn_reason" : {
|
||||
"type" : "r",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x0000",
|
||||
"description" : "Shutdown reason"
|
||||
}
|
||||
}
|
||||
},
|
||||
"logfifo_mng" : {
|
||||
"address" : "0xE",
|
||||
"width" : "32",
|
||||
"description" : "Log-FIFO Management",
|
||||
"fields" : {
|
||||
"logfifo_level" : {
|
||||
"type" : "r",
|
||||
"bit_len" : "8",
|
||||
"reset" : "0x00",
|
||||
"description" : "Log-FIFO level"
|
||||
},
|
||||
"logfifo_ovl" : {
|
||||
"type" : "r",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Log-FIFO overflow flag"
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "22",
|
||||
"description" : "Reserved bits"
|
||||
},
|
||||
"address" : "0xE",
|
||||
"width" : "32",
|
||||
"description" : "Log-FIFO Management",
|
||||
"fields" : {
|
||||
"logfifo_level" : {
|
||||
"type" : "r",
|
||||
"bit_len" : "8",
|
||||
"reset" : "0x00",
|
||||
"description" : "Log-FIFO level"
|
||||
},
|
||||
"logfifo_ovl" : {
|
||||
"type" : "r",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Log-FIFO overflow flag"
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "22",
|
||||
"description" : "Reserved bits"
|
||||
},
|
||||
"clr_logfifo" : {
|
||||
"type" : "wp",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Clears Log-FIFO (Self-Clearing)"
|
||||
}
|
||||
}
|
||||
},
|
||||
"type" : "wp",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0x0",
|
||||
"description" : "Clears Log-FIFO (Self-Clearing)"
|
||||
}
|
||||
}
|
||||
},
|
||||
"logfifo_out" : {
|
||||
"address" : "0xF",
|
||||
"width" : "32",
|
||||
"type" : "rp",
|
||||
"reset" : "U",
|
||||
"description" : "Log-FIFO output data: a new data is read from the FIFO at each read access"
|
||||
},
|
||||
"address" : "0xF",
|
||||
"width" : "32",
|
||||
"type" : "rp",
|
||||
"reset" : "U",
|
||||
"description" : "Log-FIFO output data: a new data is read from the FIFO at each read access"
|
||||
},
|
||||
"shutdn_thres" : {
|
||||
"address" : "0x20",
|
||||
"width" : "32",
|
||||
"description" : "Shut-Down threshold registers (STATUS_WIDTH consecutive registers, one for every input status bit, starting from offset 0x20)",
|
||||
"fields" : {
|
||||
"value" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x0A",
|
||||
"description" : "Shut-Down threshold value"
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "16",
|
||||
"description" : "Reserved bits"
|
||||
}
|
||||
}
|
||||
"address" : "0x20",
|
||||
"width" : "32",
|
||||
"description" : "Shut-Down threshold registers (STATUS_WIDTH consecutive registers, one for every input status bit, starting from offset 0x20)",
|
||||
"fields" : {
|
||||
"value" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x0A",
|
||||
"description" : "Shut-Down threshold value"
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "16",
|
||||
"description" : "Reserved bits"
|
||||
}
|
||||
}
|
||||
},
|
||||
"logging_thres" : {
|
||||
"address" : "0x30",
|
||||
"width" : "32",
|
||||
"description" : "Logging threshold registers (STATUS_WIDTH consecutive registers, one for every input status bit, starting from offset 0x30)",
|
||||
"fields" : {
|
||||
"value" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x05",
|
||||
"description" : "Logging threshold value"
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "16",
|
||||
"description" : "Reserved bits"
|
||||
}
|
||||
}
|
||||
"address" : "0x30",
|
||||
"width" : "32",
|
||||
"description" : "Logging threshold registers (STATUS_WIDTH consecutive registers, one for every input status bit, starting from offset 0x30)",
|
||||
"fields" : {
|
||||
"value" : {
|
||||
"type" : "w",
|
||||
"bit_len" : "16",
|
||||
"reset" : "0x05",
|
||||
"description" : "Logging threshold value"
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
"bit_len" : "16",
|
||||
"description" : "Reserved bits"
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
},
|
||||
{
|
||||
"ip_name" : "signal_sequencer",
|
||||
"bus" : "seq",
|
||||
"addr_hi_bit" : "8",
|
||||
"addr_lo_bit" : "8",
|
||||
"description" : "Generic Signal-Sequencer",
|
||||
"sub_blocks" : {
|
||||
"generic_sequencer_15" : {
|
||||
"instance" : "",
|
||||
"process" : "enabled",
|
||||
"offset" : "0x000"
|
||||
}
|
||||
}
|
||||
}]
|
||||
"ip_name" : "signal_sequencer",
|
||||
"bus" : "seq",
|
||||
"addr_hi_bit" : "8",
|
||||
"addr_lo_bit" : "8",
|
||||
"description" : "Generic Signal-Sequencer",
|
||||
"sub_blocks" : {
|
||||
"generic_sequencer_15" : {
|
||||
"instance" : "",
|
||||
"process" : "enabled",
|
||||
"offset" : "0x000"
|
||||
}
|
||||
}
|
||||
}]
|
||||
|
|
|
|||
|
|
@ -3,7 +3,7 @@
|
|||
"bus" : "csr",
|
||||
"addr_width" : "4",
|
||||
"description" : "This block is the 1MBaud UART interface for alerts",
|
||||
"notes" : "The 1MBaud UART is used as a receiver only UART for STM8 alert data, mapping received byte codes to trigger pulse, with enables. The core logic is generated from the Altera soft IP suite. The RX register is used to give the CPU access to the received data, with the READ_DATA fields giving the received byte. When reading the register, if read data is valid (READ_DATA_VALID bit), the byte is 'popped' from the receiver fifo queue. Parity error status is given (PARITY_ERROR bit), along with the data valid and a count of queued received data (READ_DATA_AVAIL bits). The CONTROL register allows the enabling of receive interrupts (RD_INT_EN), as well as (on reads) the status of the interrupt (RD_INT). All the fields associated with transmission are not used. For the generation of emergency shutdown request, the CODES register is used to define the 3 upper bit codes for the four events (by default they are the values defined at https://confluence.gisapps.co.uk/display/SOMG/Rolling+ADC+UART+Alerts). The OVRG_EN register is a bitmap for the ADC ordinals of the over-range event. Reception of an over-range event with a bit set in this register, as indexed by the ordinal, will generate an over-range trigger output. Similarly for the UNRG_EN register and under-range trigger, the OVRG_RTN_EN register and the over-range return trigger and the UNRG_RTN_EN register and under-range return trigger outputs. The block will generate an interrupt if the over- or under-range trigger outputs pulse (and thus enabled by the enable registers being non-zero), or by the UART core, enabled by the UART's CONTROL register.",
|
||||
"notes" : "The 1MBaud UART is used as a receiver only UART for STM8 alert data, mapping received byte codes to trigger pulse, with enables. The core logic is generated from the Altera soft IP suite. The RX register is used to give the CPU access to the received data, with the READ_DATA fields giving the received byte. When reading the register, if read data is valid (READ_DATA_VALID bit), the byte is 'popped' from the receiver fifo queue. Parity error status is given (PARITY_ERROR bit), along with the data valid and a count of queued received data (READ_DATA_AVAIL bits). The CONTROL register allows the enabling of receive interrupts (RD_INT_EN), as well as (on reads) the status of the interrupt (RD_INT). All the fields associated with transmission are not used. For the generation of emergency shutdown request, the CODES register is used to define the 3 upper bit codes for the four events (by default they are the values defined at https://congis.atlassian.net/wiki/spaces/SOMG/pages/4751164434/Rolling+ADC+UART+Alerts). The OVRG_EN register is a bitmap for the ADC ordinals of the over-range event. Reception of an over-range event with a bit set in this register, as indexed by the ordinal, will generate an over-range trigger output. Similarly for the UNRG_EN register and under-range trigger, the OVRG_RTN_EN register and the over-range return trigger and the UNRG_RTN_EN register and under-range return trigger outputs. The block will generate an interrupt if the over- or under-range trigger outputs pulse (and thus enabled by the enable registers being non-zero), or by the UART core, enabled by the UART's CONTROL register.",
|
||||
"registers" : {
|
||||
"ip_id" : {
|
||||
"address" : "0",
|
||||
|
|
@ -21,7 +21,7 @@
|
|||
"bit_len" : "8",
|
||||
"reset" : "0xFF",
|
||||
"description" : "Manufacturer number"
|
||||
|
||||
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
|
|
@ -46,7 +46,7 @@
|
|||
"bit_len" : "8",
|
||||
"reset" : "0x00",
|
||||
"description" : "Major number"
|
||||
|
||||
|
||||
},
|
||||
"reserved" : {
|
||||
"type" : "rsv",
|
||||
|
|
@ -198,13 +198,13 @@
|
|||
"type" : "rwp",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0",
|
||||
"description" : "Read interrupt enable"
|
||||
"description" : "Read interrupt enable"
|
||||
},
|
||||
"wr_int_en" : {
|
||||
"type" : "rwp",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0",
|
||||
"description" : "Write interrupt enable"
|
||||
"description" : "Write interrupt enable"
|
||||
},
|
||||
"reserved0" : {
|
||||
"type" : "rsv",
|
||||
|
|
@ -215,13 +215,13 @@
|
|||
"type" : "rwp",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0",
|
||||
"description" : "Read interrupt active (actually read-only, but violates mixing rules)"
|
||||
"description" : "Read interrupt active (actually read-only, but violates mixing rules)"
|
||||
},
|
||||
"wr_int" : {
|
||||
"type" : "rwp",
|
||||
"bit_len" : "1",
|
||||
"reset" : "0",
|
||||
"description" : "Write interrupt active (actually read-only, but violates mixing rules)"
|
||||
"description" : "Write interrupt active (actually read-only, but violates mixing rules)"
|
||||
},
|
||||
"reserved1" : {
|
||||
"type" : "rsv",
|
||||
|
|
@ -232,7 +232,7 @@
|
|||
"type" : "rwp",
|
||||
"bit_len" : "8",
|
||||
"reset" : "0",
|
||||
"description" : "Write FIFO space available (actually read-only, but violates mixing rules)"
|
||||
"description" : "Write FIFO space available (actually read-only, but violates mixing rules)"
|
||||
},
|
||||
"reserved2" : {
|
||||
"type" : "rsv",
|
||||
|
|
@ -242,4 +242,4 @@
|
|||
}
|
||||
}
|
||||
}
|
||||
}]
|
||||
}]
|
||||
|
|
|
|||
|
|
@ -5,7 +5,7 @@
|
|||
"addr_lo_bit" : "9",
|
||||
"addr_width" : "5",
|
||||
"description": "10-Gigabit Ethernet Offload Engine",
|
||||
"notes" : "Please refer to https://confluence.gisapps.co.uk/display/EL/GIS+10-Gigabit-Ethernet+solution for details",
|
||||
"notes" : "Please refer to https://congis.atlassian.net/wiki/spaces/EL/pages/26765200629/GIS+10-Gigabit-Ethernet+solution for details",
|
||||
"sub_blocks" : {
|
||||
"local" : {
|
||||
"instance" : "",
|
||||
|
|
@ -416,4 +416,4 @@
|
|||
"description" : "Clear GMII RX bridge full flag"
|
||||
}
|
||||
}
|
||||
}]
|
||||
}]
|
||||
|
|
|
|||
Loading…
Add table
Add a link
Reference in a new issue