hdl: disable altera spi controller insertSync parameter for ad9361

this parameter was corrupting bits on read.
This commit is contained in:
Robert Ghilduta 2017-03-28 01:32:43 -07:00 • committed by Robert Ghilduta
commit 9bb7fe7d16

View file

@ -43,7 +43,7 @@ set_instance_parameter_value lms_spi {clockPolarity} {1}
set_instance_parameter_value lms_spi {dataWidth} {8}
set_instance_parameter_value lms_spi {disableAvalonFlowControl} {0}
set_instance_parameter_value lms_spi {insertDelayBetweenSlaveSelectAndSClk} {0}
set_instance_parameter_value lms_spi {insertSync} {1}
set_instance_parameter_value lms_spi {insertSync} {0}
set_instance_parameter_value lms_spi {lsbOrderedFirst} {0}
set_instance_parameter_value lms_spi {masterSPI} {1}
set_instance_parameter_value lms_spi {numberOfSlaves} {1}