bladeRF Test Checklist ================================================================================ This file serves as a quick summary of tests that should be run regularly by developers to detect defects and regressions. Over time these procedures should become automated, and more fine-grained tests should be introduced. At that time, this document shall be updated to reflect usage of the automated tests. When running through the items contained in this file, developers should maintain an annotated copy of this file, containing: * The date when tests were run * The device versions used when performing tests * "Checks" in the "boxes" ([ ]) and any associated observations or notes -------------------------------------------------------------------------------- Build Tests ================================================================================ ## FPGA Bitstream ## * Perform FPGA images build with Quartus II 13.1 for the following: * Revision: hosted * [ ] Size: x40 * [ ] Size: x115 * Revision: atsc_tx * [ ] Size: x40 * [ ] Size: x115 ## FX Firmware ## * Perform firmware builds for both variants: * [ ] Release * [ ] Debug * Ensure the build operates on the FX3 SDKs supported operating systems: * [ ] Windows * [ ] Linux ## Host software ## Verify that build and installation completes from the top-level, from a clean build directory, for each of below configurations. Keep the "treat warnings as errors" option enabled; warnings should be regarded as defects. With a device attached, use the following commands to verify the build has installed and that the desired backend is being used: ```bladeRF-cli -e 'version' -e 'info'``` Additionally, ensure ```libbladeRF_test_c``` and ```libbladeRF_test_cpp``` build and run. * [ ] Debug build: ```-DCMAKE_BUILD_TYPE=Debug``` * [ ] Release build: ```-DCMAKE_BUILD_TYPE=Release -DTAGGED_RELEASE=Yes``` Linux/OSX: Perform the above builds with the following: * [ ] GCC * [ ] Clang * [ ] Clang `ccc-analyzer` & `scan-build` (with `-maxloop 100` or greater) * Any items in the static analysis report should be regarded as defects. * [ ] Windows: Build with support for both libusb and the Cypress backend. This should be the default behavior when both present on the build system. * [ ] Windows: Build with support for only one of the two available backends. * [ ] Windows: Perform builds targeting Win32 and x64 * [ ] Build with documentation (from a clean CMake directory): ```-DENABLE_DOCUMENTATION=ON``` * Any Doxygen warnings should be regarded as defects. At a minimum, builds with the following compilers should be verified: * [ ] GCC 4.8.x * [ ] Clang 3.4 * [ ] Visual Studio 2012 * This has little to no C99 support. * [ ] Visual Studio 2013 * This introduced some C99 headers. Functional Tests ================================================================================ Most of the functional tests listed here are system-wide integration tests. Unit tests, Built-in self-tests (BISTs), and top-level test-benches are very much desirable additions for improving QA and testing efforts. (Patches are always welcome!) When appropriate, each test for both USB 2.0 and USB 3.0 connections. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ## FX3 Firmware Compliance Testing ## The USB IF Compliance test tools shall be used to identify missing/incorrect functionality. Run these and record any failures or warnings. * [USB30CV tool](http://www.usb.org/developers/tools/#usb30tools) * [USB20CV tool](http://www.usb.org/developers/tools/usb20_tools/#usb20cv) - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ## SPI Flash Access ## The following items are intended to exercise SPI flash accesses. ### OTP region readback ### There should be no warnings, info, or debug messages reported while performing this operations. * [ ] ```bladeRF-cli -e 'info' -v debug``` should report the serial number. ### Calibration region readback ### * [ ] ```bladeRF-cli -e 'info' -v debug``` should report the VCTCXO DAC calibration and FPGA size. There should be no warnings, info, or debug messages reported while performing this operations. ### Writing calibration data ### During the following steps, There should be no error, warning, info, or debug messages other than the information about flash page read operations. * [ ] Back up calibration data via: ```bladeRF-cli -e 'flash_backup cal.bin cal' -v debug``` * [ ] Write new calibration data (using the appropriate FPGA size) via: ```bladeRF-cli -e 'flash_init_cal 40 0x8000' -v debug``` * [ ] Power cycle the device and verify the new values (see the previous subsection). * [ ] Restore the original calibration data via: ```bladeRF-cli -e 'flash_restore cal.bin cal' -v debug``` * [ ] Power cycle the device and verify the new values. ### Firmware Programming ### Consider any errors or warnings to be defects during these operations. Info messages are expected, and are intended to provide the user with feedback about the status of flash operations. * [ ] Force the device back to the FX3 bootloader via: ```bladeRF-cli -e 'jump_to_boot' -v debug``` * [ ] Power cycle the device. It should continue to boot into the bootloader, instead of the firmware. * [ ] "Recover" the device and Flash firmware via the bladeRF-cli: ``` bladeRF> recover bladeRF_fw_vX.Y.Z.img bladeRF> open bladeRF> load fx3 bladeRF_fw_vX.Y.Z.img ``` * [ ] Power cycle the device and verify that it boots the desired firmware, and that the calibration data is intact: ```bladeRF-cli -e 'version' -e 'info' -v debug``` * [ ] Flash a different version of firmware via: ```bladeRF-cli -f bladeRF_fw_vA.B.C.img -v debug``` * [ ] Power cycle the device and verify that the new firmware has been loaded, and that the calibration data is correct. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ## FPGA Loading ## ### FPGA Flash-based Autoloading ### Consider any errors or warnings to be defects during these operations. Info messages are expected, and are intended to provide the user with feedback about the status of flash operations. Ensure that you do not have any FPGA bitstreams on the host set up for host-based autoloading. * [ ] Erase any previously stored FPGA images: ```bladeRF-cli -L X -v debug``` * [ ] Power cycle the device, and verify that this has not corrupted the caaalibration data or firmware: ```bladeRF-cli -e 'version' -e 'info' -v debug``` * [ ] Write an FPGA bitstream to flash: ```bladeRF-cli -L -v debug``` * [ ] Power cycle the device and verify that the firmware boots, the FPGA is loaded, and that the calibration data has not been corrupted. ```bladeRF-cli -e 'version' -e 'info' -v debug``` * [ ] Erase the FPGA and perform the associated verifications. ### Host-based Autoloading ### * [ ] (Re)add an FPGA image to an autoload directory. * [ ] Power cycle the device. * [ ] Verify that the intended FPGA is loaded: ```bladeRF-cli -e 'version' -e 'info' -v debug``` ### Manual FPGA Loading ### * [ ] Verify that FPGA loading via ```bladeRF-cli -l -v debug``` succeeds. * [ ] Verify that the expected version was loaded: ```bladeRF-cli -e 'version' -e 'info' -v debug```. Load a different version with the FPGA already loaded, and preform the verification step again. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ## Basic Device Control ## These device control operations may be performed with the bladeRF-cli, or for simplicity, third party tools, as they should utilize the same underlying `libbladeRF` API calls. A signal generator and spectrum analyzer are required for many of these items. ### Frequency Tuning ## When performing these tests, make notes of the frequencies that you are using. If issue occur, it is important to know if it is when crossing "bands" or internal device ranges. #### RX #### * [ ] Verify reception of reference signals at various frequencies in 300MHz - 3.8GHz, ***without*** an XB-200 attached. Verify reception of reference signals at various frequencies up to 3.8GHz, ***with*** an XB-200 attached, using each filter configuration: * [ ] Auto 3dB filterbank * [ ] Auto 1dB filterbank * [ ] 6m filterbank * [ ] 2m filterbank * [ ] 1.25m filterbank * [ ] Custom path #### TX #### * [ ] Verify that a VSA can receive and demodulate reference signals at frequencies in 300MHz - 3.8GHz, ***with*** an XB-200 attached. Verify that a VSA can receive and demodulate reference signals at frequencies in up to 3.8GHz, ***without*** an XB-200 attached, using each filter configuration: * [ ] Auto 3dB filterbank * [ ] Auto 1dB filterbank * [ ] 6m filterbank * [ ] 2m filterbank * [ ] 1.25m filterbank * [ ] Custom path ### Gain ### #### RX #### Supply the device with a reference signal and verify the effect of changing the gain values for: * [ ] RX LNA * [ ] RX VGA1 * [ ] RX VGA2 #### TX #### Transmit a reference signal to a VSA and verify the effect of changing the gain values for: * [ ] TX VGA1 * [ ] TX VGA2 ### Bandwidth ### #### RX #### * [ ] Supply a reference signal of a wide bandwith and verify the effect of changing the RX bandwidth. #### TX #### * [ ] Transmit a reference signal of a wide bandwith to a VSA and verify the effect of changing the TX bandwidth. ### DC Offset ### Repeat the following steps for a variety of frequency/gain combinations and make note of the results. * [ ] Use the bladeRF-cli to perform an initial ```cal lms``` at a desired frequency and gain. * [ ] In the CLI, perform a ```cal dc rx``` operation, and note the effect on received IQ values and on an FFT plot. * [ ] Create and load an RX calibration table. Verify that corrections are applied over the range of the table. * [ ] In the CLI, perform a ```cal dc tx``` operation, and transmit a tone into a VSA. Make note of the difference in the DC offset. * [ ] Create and load a TX calibration table. Verify that corrections are applied over the range of the table. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ### libbladeRF test programs ### The libbladeRF test programs are intended to exercise specific functionalities provided by the API. However, these programs inherently exercise device control functionality not included above. A selection of the ```libbladeRF_test_*``` programs is provided here to attempt to maximize coverage with a small number of programs. #### ```libbladeRF_test_ctrl``` #### This test ensures that various device control calls complete without error. Run all of its tests **without** an XB-200 attached. * [ ] ```sampling``` * [ ] ```lpf_mode``` * [ ] ```enable_module``` * [ ] ```loopback``` * [ ] ```correction``` * [ ] ```samplerate``` * [ ] ```bandwidth``` * [ ] ```gain``` * [ ] ```frequency``` * [ ] ```threads``` Run all of its tests ***with ** an XB-200 attached * [ ] ```sampling``` * [ ] ```lpf_mode``` * [ ] ```enable_module``` * [ ] ```loopback``` * [ ] ```correction``` * [ ] ```samplerate``` * [ ] ```bandwidth``` * [ ] ```gain``` * [ ] ```frequency``` * [ ] ```threads``` #### ```libbladeRF_test_rx_discont``` #### * [ ] Run this program over a variety of valid sample rates (for the particular USB connection). No discontinuities should occur. * [ ] Run this program over for sample rates that your USB controller does not support. Discontinuities should be reported. #### ```libbladeRF_test_repeater``` #### This program uses the async interface to immediately retransmit received samples. Supply a reference signal from a signal generator, and verify that it can be demodulated without failures on a VSA. Record the sample rates, bandwidths, frequencies, and stream parameters used. * [ ] Verify that transmitted samples are representative of the received signals. #### ```libbladeRF_test_timestamps``` #### This program verifies timestamp functionality. Run all available test at a variety of sample rates. Not that some tests (e.g., loopback_onoff) are not designed to support high sample rates. * [ ] ```rx_gaps``` * [ ] ```rx_scheduled``` * [ ] ```tx_onoff``` * [ ] ```tx_onoff_nowsched``` * [ ] ```tx_gmsk_bursts``` * [ ] ```loopback_onoff``` * [ ] ```format_mismatch``` * [ ] ```readback``` - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ### libbladeRF sample programs ### As these are intended to exemplify API usage, these programs must be correct. Verify that the following run as intended: * [ ] ```libbladeRF_example_open_via_serial``` * [ ] ```libbladeRF_example_sync_rxtx``` * [ ] ```libbladeRF_example_sync_rx_meta``` * [ ] ```libbladeRF_example_sync_tx_meta``` - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ## Third-party Tools ## Testing against third-party tools with bladeRF support to ensure changes have not introduced compatibility issues is highly recommended. Make note of the tool and its version, for future comparison, should any issues arise.