\page sync_rx_meta Synchronous Interface: RX with Metadata
This page describes how to use the bladeRF <a class="el"
href="group___f_n___d_a_t_a___s_y_n_c.html">Synchronous Interface</a> to
receive samples with their associated timestamp, and scheduling reception at a
specific timestamp.
The timestamp value is associated with free-running counter in the FPGA,
incrementing at the sample rate specified by bladerf_set_sample_rate(), with
each incoming sample.
<br>
<h2>Configuring the Synchronous Interface</h2>
When timestamps are desired, one must enable metadata support. This is done
through the `format` parameter of the bladerf_sync_config() function:
\snippet sync_rx_meta.c sync_config
Descriptions of the other parameters may be found in the
<a class="el" href="sync_no_meta.html">Synchronous Interface: Basic usage without metadata</a>
page.
Remember to enable the front end via bladerf_enable_module() <i>after</i>
calling bladerf_sync_config(), and <i>before</i> attempting to call
bladerf_sync_rx().
Also ensure that bladerf_sync_config() has been called before attempting to read
timestamps via bladerf_get_timestamp().
When using the ::BLADERF_FORMAT_SC16_Q11_META format, a ::bladerf_metadata
structure must be passed to bladerf_sync_rx(). One should zero the contents of
this structure prior to using it.
<br>
<h2>Receiving Samples Immediately with Timestamps</h2>
As shown in the following snippet, the ::bladerf_metadata structure (`meta`) is
first zeroed out, and then the metadata flags (`meta.flags`) are set to
::BLADERF_META_FLAG_RX_NOW. This flag denotes that RX samples should returned
immediately, rather than scheduled for a specific RX timestamp.
Once bladerf_sync_rx() returns, the ::bladerf_metadata.timestamp field may
be read (`meta.timestamp`). Under normal conditions, this timestamp is
associated with the first sample in the provided buffer, with the remaining
samples in the buffer being contiguous (i.e., there is no timestamp gap between
them). The ::bladerf_metadata.actual_count field should indicate
that the requested number of samples have been read into the supplied buffer.
However, if an RX overrun has occurred, as indicated by the
::BLADERF_META_STATUS_OVERRUN bit being set in the ::bladerf_metadata.status
field (`meta.status`), a sample discontinuity will have occurred. Generally,
this overrun condition may occur if the time between calls to bladerf_sync_rx()
is too long, or too few/small buffers were provided to bladerf_sync_config().
In the case of an overrun, the ::bladerf_metadata's `actual_count` value
is set to the number of contiguous samples read into the supplied buffer.
This value will be less than the requested number of samples, so be sure
not to read past this number of samples.
\snippet sync_rx_meta.c rx_meta_now_example
<br>
<h2>Receiving Samples at a Specified Timestamps</h2>
To schedule reception at a specific timestamp, set the ::bladerf_metadata.flags
field to 0, and write the desired timestamp to the ::bladerf_metadata.timestamp field.
A call to bladerf_sync_rx() may then be used to read the specified number of samples
at the timestamp indicated in metadata structure. Ensure that the timeout provided to
bladerf_sync_rx() is sufficiently large, such that the function call does not time
out before the desired timestamp occurs.
When scheduling the first RX, it is generally helpful to first read the
stream's timestamp counter and advance it by a known duration. This is shown in
the below example code.
Note that the caller is responsible for advancing the timestamp field each
time bladerf_sync_rx() is called.
\snippet sync_rx_meta.c rx_meta_sched_example
The description of the ::BLADERF_META_STATUS_OVERRUN flag and the the
::bladerf_metadata.actual_count field from the previous section applies here as well.
*/