v1.7.1 (2018-12-21)
--------------------------------
* tx.c: fix memory leak in CSV-to-SC16Q11 conversion (fixes #694)
* cmd.c: cleanup command definitions, code formatting
* main.c: remove vestigial printfs in open_device()
* Updated documentation for adding new commands
* calibrate.c, flash_*.c: updates for libbladeRF v2.2.0
v1.7.0 (2018-10-30)
--------------------------------
* Add libedit support (#591)
* Show RF routing in 'print hardware' on bladerf1 devices (#608)
* Display manufacturer and product strings in 'probe', 'info' (#624)
* Ensure device is initialized after deferred open (#612)
* Use "degrees C" on temperature instead of the degrees symbol
* Add flash size to 'info' command (#634)
* Handle already-open devices on 'probe' (#648)
* Add support for "J51-1" and "Miniexp-1" as trigger signals (#656)
* Display FPGA configuration source on 'version' (#662)
* Print supported ranges for sample rate, bandwidth, frequency
* Fix missing return in error case (#666)
v1.6.1 (2018-08-24)
--------------------------------
This version depends on libbladeRF v2.0.1 or later.
* "set loopback" help dialog aware of board type (#566)
* host: libbladeRF: Rename clock select option
* host: bladeRF-cli: Add 200 ms delay before probing PLL lock status (#587)
* host: add nanosleep shim for Windows (#589)
v1.6.0 (2018-08-13)
--------------------------------
This version depends on libbladeRF v2.0.0 or later.
* Initial public release with bladeRF 2.0 ("Micro") support
* Adds support for MIMO RX and TX using "channel=" parameter on rx/tx config
* Various code quality fixups
v1.5.2 (2018-03-26)
--------------------------------
This version is part of development series of changes, not an official release.
This version depends upon libbladeRF v1.9.1 or later.
* Support for bladeRF Micro
* No longer initializes the bladeRF before loading a new FPGA image, to avoid
potential catch-22 problems
v1.5.1 (2017-12-07)
--------------------------------
This version depends upon libbladeRF v1.8.1 or later.
* Minor fix-ups
v1.5.0 (2017-07-01)
--------------------------------
This version depends upon libbladeRF v1.8.0 or later.
* Added support for Automatic Gain Control
v1.4.0 (2016-01-05)
--------------------------------
This version depends upon libbladeRF v1.7.0 or later.
* Added XB-300 support
* Added synchronization trigger support
* Added set `smb_mode` and print `smb_mode` support
- This supersedes the `mimo` command, which is now marked *deprecated*.
* Fixed CLI exit on FW/FPGA version mismatch
* Fixed build on big-endian machines.
v1.3.1 (2016-01-05)
--------------------------------
This version depends upon libbladeRF v1.5.1 or later.
* Addressed warnings that occur with GCC -Os flag.
v1.3.0 (2015-12-31)
--------------------------------
This version depends upon libbladeRF v1.5.0 or later.
* Marked 'set frequency <value>' deprecated.
- Use 'set frequency rx <value>' or 'set frequency tx <value>'
* Updated DC calibration routines for improved accuracy and to avoid lockups
* Added print/set support for VCTCXO tamer mode
* Added fw_log command
* Added ability to set SMB master frequency
* Added print/set support FPGA RX FIFO input mux (rx_mux)
* Fixed regression in set xb_gpio[_dir] register-level access
* Fixed issues with validating and applying rational sample rates
* Output formatting cleanup
v1.2.1 (2015-07-16)
--------------------------------
This version depends upon libbladeRF v1.4.1 or later.
* Fixed issue where transmission could be truncated due to TX RFFE being
turned off before sample buffers reach the transceiver.
* Fixed errors and inconsistencies in interactive command help text.
v1.2.0 (2015-06-30)
--------------------------------
This version depends upon libbladeRF v1.4.0 or later.
* Added support for semicolon command separators
* Added 'print trimdac' support. (Requires FPGA v0.3.2)
* Fixed libbladeRF return value translation bugs
v1.1.2 (2015-02-28)
--------------------------------
This version depends upon libbladeRF v1.2.1 or later.
* Fixed and improved help text and manual page generation.The doc generation
scripts should now be compatible with formats used by pandoc 1.12.x and
1.13.x.
v1.1.1 (2015-01-31)
--------------------------------
This version depends upon libbladeRF v1.2.0 or later.
* Updated LMS bit definitions for 'peek/poke lms' commands to include bits
previously marked "spare."
* Fixed a documentation build issue caused by help2man usage.
v1.1.0 (2014-12-23)
--------------------------------
This version depends upon libbladeRF v1.1.0 or later.
* The -p/--probe command line option now causes bladeRF-cli to return a
non-zero return value if no devices are found. This is intended to allow
shell scripts to easily check if devices are (not) present.
* The 'probe' command now takes an optional 'strict' argument to specify that
the lack of any identified devices should be treated as an error, which
would cause scripts or a list of '-e' command line arguments to terminate
immediately.
* Before entering interactive mode, script parsing, or '-e' option execution,
bladeRF-cli now searches for devices in bootloader modes and prompts the
user to run 'help recover' for instructions on loading firmware onto these
devices. This replaces the [INFO] log message previously printed by
lower-level libbladeRF code.
v1.0.0 (2014-11-29)
--------------------------------
This version depends upon libbladeRF v1.0.0 or later.
* Major version number incremented.
* This denotes that no further reverse-incompatible command changes shall be
introduced without a change to the major version number.
v0.12.0 (2014-10-30)
--------------------------------
This version depends upon libbladeRF v0.17.0 or later.
* Migrated rx/tx commands to libbladeRF's synchronous interface
* Introduced support of '#' line comments
* Changed argument order of xb command to be more intuitive
* Cleaned up help text and addressed discrepancies between help text and
associated commands
* Misc. minor bug fixes.
v0.11.1 (2014-07-24)
--------------------------------
This version depends upon libbladeRF v0.16.2 or later.
* Added missing FW loopback mode option
* Fixed help text and doc generation
* Return value corrections and parameter handling fixes
* Misc. typo and help-text touch-ups
* Minor Windows build touch-ups
v0.11.0 (2014-07-04)
--------------------------------
This version depends upon libbladeRF v0.16.0 or later.
* Added experimental DC calibration table generation
- Changed usage of 'calibrate' command
- Move 'correct' functionality into 'calibrate' command
* Added '-e <command>' support
* Added "pretty print" of LMS registers
* Fixed '<rx|tx> wait' hang-ups
* Differentiate between "file not found" and file I/O errors
* Addressed a crash in the 'tx' command
* Fixed handling of unterminated quotes
v0.10.8 (2014-05-17)
--------------------------------
* Updates to corresponding to libbladeRF API changes
* Removed device reset after flashing firmware
* Added interactive help text command added to allow man page to be generated
without needing a script to scrape text.
* Preliminary support for XB-200
v0.10.7 (2014-03-18)
--------------------------------
* Added libc version check to determine if -lrt is required
* Windows: Fixed reading binary files in for transmission
* Serial # is now printed in`flash_image`output
* Help text fixes and improvements
* Added additional parameter range checks
* Minor source tree reorganization
v0.10.6 (2014-03-07)
--------------------------------
* Removed bladerf_close() call after bladerf_device_reset()
- This function call would yield an attempt to close a stale device handle,
causing BSoDs in Windows.
v0.10.5 (2014-02-27)
--------------------------------
* Error message corrections
* Fixes to RXVGA1-related textual output
v0.10.4 (2014-02-05)
--------------------------------
* Loopback support added to print/set commands
* Print "first available" instead of "(null") when no device is specified via
the -d option.
* Help text updates
v0.10.3 (2014-01-26)
--------------------------------
* Fix for buffer corruption in TX stream (tx command)
* Added rx/tx timeout configuration
* Fixed tab-completion for "file=<tab>"
* Clamp out-of-range values from CSV files
v0.10.2 (2014-01-18)
--------------------------------
* Supporting rational sample rates via the libbladeRF rational sample rate i/f
* Fixes in the 'correct' command, pertaining to the libbladeRF 0.12.0
changes.
* RX/TX command error message fixes
v0.10.1 (2014-01-09)
--------------------------------
* Fixed a race condition in starting up RX/TX worker threads
* Addressed "Peripheral access failure" error messages
* Added FPGA state check in calibration command
v0.10.0 (2013-12-01)
--------------------------------
* Added 'correct' command for manual DC offset an IQ balance adjustments
* Fixed misc. defects detected via Coverity scans
v0.9.0 (2013-11-28)
--------------------------------
* Added command for initializing, backing up, and storing the contents of
SPI flash
v0.8.0 (2013-11-28)
--------------------------------
* Added rx/tx 'wait' operation
* Added 'run' command to run scripts from the CLI, or from within other scripts
* Added 'echo' command for debugging purposes
* Added support for quoted arguments
* Removed extraneous error messages
* Removed exit-with-failure if no device is connected
v0.7.1 (2013-11-08)
--------------------------------
* Fixed incorrect write size check for 'rx' with 'format=bin'
* Fixed swap of --version and --lib-version
* Added GPLv2 headers to source files
* Windows: Fixed issue where binary files were opened in text mode
* Fixed misc. defects detected via Coverity scans
v0.7.0 (2013-10-21)
--------------------------------
* Fixed incorrect file write size
* Fixed incorrect return values and potential memory leaks
* Windows compatibility fixes
v0.6.0 (2013-10-14)
--------------------------------
* 'rx' and 'tx' commands updated to use asynchronous data streaming interface
* 'mimo' command added
* 'info' command added
v0.5.0 (2013-10-05)
--------------------------------
* Removed device info from 'version' command, with the intent of
moving it to a separate command (which wasn't introduced until v0.6.0).
v0.4.2 (2013-10-04)
--------------------------------
* Cleaned up 'version' command output
* Fixed warning that broke Windows build (with /WX)
v0.4.1 (2013-10-03)
--------------------------------
* Updated version-related code to account for libbladeRF's addition
of the bladerf_version structure
* Added simple fgets-based interactive mode support, as an alternative
for systems without libtecla support (e.g., Windows)
* Windows build/compatibility fixes
* Added 'erase' command to allow regions of SPI flash to be erased
v0.4.0 (2013-09-02)
--------------------------------
* Added -v option to control libbladeRF verbosity
* Added differentiation between a failed device probe and the
lack of any attached devices
* Removed data endianess in rx/tx commands. The data is stored
in the host's endianness.
* Changed default CSV->binary filename to be not Unix-specific
* Fixed return value issues that caused the CLI to exit on non-fatal errors
v0.3.1 (2013-08-28)
----------------------------------
* Added filename expansion support
- Converts ~/some/path to /home/user/some/path on *nix-based systems
* Fixed OSX linking issue
* Fixed USB bus/address swap in 'probe' output
* Fixed crash in parsing CSV data
* Added more descriptive error messages
v0.3.0 (2013-08-22)
----------------------------------
* First functional version
- Earlier versions were generally only useful for tests and debugging
the preliminary version of libbladeRF.