gis_logo.png

Datasheet for the TEST GIS Soft IP Embedded Logic

Register Definitions

test This block the top leve test bech
Register Name Byte Addr Offset Field Bits Type subtype Reset Description
CSR_TEST_CONTROL 0x0 4 Testbench simulation control
ERROR 0 w 0 Set error state
DO_STOP 1 w 0 Request simulation to stop
DO_FINISH 2 w 0 Request simulation to finish
PARTIAL_TEST 3 w 0 Flag that not all tests were run
CSR_TEST_TIME_COUNT 0x4 32 r 0 System clock timing counter
CSR_TEST_TIMEOUT 0x8 31 w 10000000 Simulation timeout (in clock cycles)
CSR_TEST_CONFIG_CLK_FREQ 0xc 9 r 0 Clock frequency configuration values
CSR_TEST_SCRATCH 0x74 32 w 0 Scratch Reg to debug sim
CSR_TEST_UART_PEI_DATA_OUT 0x78 8 wp 0 Uart Data out. Writes Data to PEI
CSR_TEST_UART_PEI_DATA_IN 0x7c 8 r 0 Uart Data In received from PEI UART
CSR_TEST_UART_PEI_STATUS 0x80 3 Uart status Register
ACK_W 0 r 0 Acknowledge write
READ_AVAILABLE 1 r 0 Read data available (write ACK R to reset)
ACK_R 2 w0 0 Acknowledge read data

Register/field type key:

TypeDescription
cConstant, with value defined by "reset" attribute
rsvSame as constant, except no reset value and always 0. Can be mixed with write types.
wWrite register (and read—no write only type). Register defined in register block and reset to "reset" attribute value. Split into fields (if applicable) for signalling and output, where attribute associated with fields, not register.
wpWrite with pulse. Register is not declared in block, but write bus split into fields as output port signals, and a pulse generated on write to register address. Register reads back 0. The "reset" attribute is for documentation only, as set externally.
w0Same as w, but auto-clears to 0 (and thus always reads as 0). At output port, signal will go high for one cycle when bit is written with a 1 (no effect if written to a 0). No "reset" attribute, as must always be 0.
rRead only value. Input ports generated for each field (where applicable), and concatenated on returned read data bus.
rpSimilar to r, but a pulse generated on a read access to the register address to allow peripheral logic to update value. The "reset" attribute is for documentation only, as set externally.
rwpSimilar to wp, but also generates a (separate) pulse on a read access to the register
bitdefDefines the bits used in the read, set, clear registers
  
SubypeDescription
unsignedRegister/field is specified as an unsigned value.
signedRegister/field is specified as a signed value.
<blank>Register/field sign status is not explicitly defined and defaults to unsigned.

 


Copyright © 2026 Global Inkjet Systems. Generated by gen_htm.py —2026-11-13 21:11