gis_logo.png

Datasheet for the ENET_2G5_OE_0 GIS Soft IP Embedded Logic

Register Definitions

Offset in core for bus CSR : 0x00014000

enet_2g5_oe_0 2.5-Gigabit Ethernet Offload Engine
Register Name Byte Addr Offset Field Bits Type subtype Reset Description
CSR_ENET_2G5_OE_0_IP_ID 0x0 32 Unique ID for this IP block
IP_NUMBER 7:0 c 0x23 IP identifier number
MFR_NUMBER 15:8 c 0xFF Manufacturer number
RESERVED 31:16 rsv 0 Reserved bits
CSR_ENET_2G5_OE_0_IP_VER 0x4 32 IP Version
MINOR_NUMBER 7:0 c 0x00 Minor number
MAJOR_NUMBER 15:8 c 0x00 Major number
RESERVED 31:16 rsv 0 Reserved bits
CSR_ENET_2G5_OE_0_SGMII 0x64 4 sgmii status
IS_1G 0 r 0 1gb not 100m or 10m
ACTIVITY 1 r 0 tx rx activity
LINK_UP 2 r 0 link_up
AUTONEGOTIATED 3 r 0 link autonegotiated

Register/field type key:

TypeDescription
cConstant, with value defined by "reset" attribute
rsvSame as constant, except no reset value and always 0. Can be mixed with write types.
wWrite register (and read—no write only type). Register defined in register block and reset to "reset" attribute value. Split into fields (if applicable) for signalling and output, where attribute associated with fields, not register.
wpWrite with pulse. Register is not declared in block, but write bus split into fields as output port signals, and a pulse generated on write to register address. Register reads back 0. The "reset" attribute is for documentation only, as set externally.
w0Same as w, but auto-clears to 0 (and thus always reads as 0). At output port, signal will go high for one cycle when bit is written with a 1 (no effect if written to a 0). No "reset" attribute, as must always be 0.
rRead only value. Input ports generated for each field (where applicable), and concatenated on returned read data bus.
rpSimilar to r, but a pulse generated on a read access to the register address to allow peripheral logic to update value. The "reset" attribute is for documentation only, as set externally.
rwpSimilar to wp, but also generates a (separate) pulse on a read access to the register
bitdefDefines the bits used in the read, set, clear registers
  
SubypeDescription
unsignedRegister/field is specified as an unsigned value.
signedRegister/field is specified as a signed value.
<blank>Register/field sign status is not explicitly defined and defaults to unsigned.

Usage Notes

 


Copyright © 2024 Global Inkjet Systems. Generated by gen_htm.py —2024-6-19 16:50