gis_logo.png

Datasheet for the GENERIC_VERSIONING GIS Soft IP Embedded Logic

Register Definitions

generic_versioning This block is the generic versioning
Register Name Byte Addr Offset Field Bits Type subtype Reset Description
CSR_GENERIC_VERSIONING_IP_ID 0x0 32 Unique ID for this IP block
IP_NUMBER 7:0 c 0x09 IP identifier number
MFR_NUMBER 15:8 c 0xFF Manufacturer number
RESERVED 31:16 rsv 0 Reserved bits
CSR_GENERIC_VERSIONING_IP_VER 0x4 32 Bits[7:0] = Minor version number, Bits[15:8] = Major version number, etc.
MINOR_NUMBER 7:0 c 0x02 Minor number
MAJOR_NUMBER 15:8 c 0x00 Major number
RESERVED 31:16 rsv 0 Reserved bits
CSR_GENERIC_VERSIONING_FW_VER_ZERO 0x8 16 c 1 Firmware version zeroth number (default overridden in Jenkins build)
CSR_GENERIC_VERSIONING_FW_VER_ONE 0xc 16 c 20000 Firmware version first number (default overridden in Jenkins build)
CSR_GENERIC_VERSIONING_FW_VER_TWO 0x10 16 c 0 Firmware version second number (default overridden in Jenkins build)
CSR_GENERIC_VERSIONING_FW_VER_THREE 0x14 16 c 0 Firmware version third number (default overridden in Jenkins build)

Register/field type key:

TypeDescription
cConstant, with value defined by "reset" attribute
rsvSame as constant, except no reset value and always 0. Can be mixed with write types.
wWrite register (and read—no write only type). Register defined in register block and reset to "reset" attribute value. Split into fields (if applicable) for signalling and output, where attribute associated with fields, not register.
wpWrite with pulse. Register is not declared in block, but write bus split into fields as output port signals, and a pulse generated on write to register address. Register reads back 0. The "reset" attribute is for documentation only, as set externally.
w0Same as w, but auto-clears to 0 (and thus always reads as 0). At output port, signal will go high for one cycle when bit is written with a 1 (no effect if written to a 0). No "reset" attribute, as must always be 0.
rRead only value. Input ports generated for each field (where applicable), and concatenated on returned read data bus.
rpSimilar to r, but a pulse generated on a read access to the register address to allow peripheral logic to update value. The "reset" attribute is for documentation only, as set externally.
rwpSimilar to wp, but also generates a (separate) pulse on a read access to the register
bitdefDefines the bits used in the read, set, clear registers
  
SubypeDescription
unsignedRegister/field is specified as an unsigned value.
signedRegister/field is specified as a signed value.
<blank>Register/field sign status is not explicitly defined and defaults to unsigned.

Usage Notes

NB: this block is a key component that is parsed externally, and cannot be renamed with major number tags in order to be processed correctly. Therefore do not modify the source code for this block. If a change is required for a project then a whole new component will be necessary and this signed off in review by the embedded logic line manager.

 


Copyright © 2024 Global Inkjet Systems. Generated by gen_htm.py —2024-10-30 09:43