Datasheet for the FPM_CTRL_7 GIS Soft IP Embedded Logic

Register Definitions

Offset in core for bus CSR : 0x00020000

fpm_ctrl_7 This block is the fire pulse manager control
Register Name Byte Addr Offset Field Bits Type subtype Reset Description
CSR_FPM_CTRL_7_IP_ID 0x0 32 Unique ID for this IP block
IP_NUMBER 7:0 c 0x14 IP identifier number
MFR_NUMBER 15:8 c 0xFF Manufacturer number
RESERVED 31:16 rsv 0 Reserved bits
CSR_FPM_CTRL_7_IP_VER 0x4 32 IP Version
MINOR_NUMBER 7:0 c 0x05 Minor number
MAJOR_NUMBER 15:8 c 0x07 Major number
RESERVED 31:16 rsv 0 Reserved bits
CSR_FPM_CTRL_7_FPM_CONFIG 0x8 10 Configuration values for the FPM
CH_NUM 3:0 r 0 Number of channels
SEB_EPD_LOGIC_PRESENT 4 r 0 0 => SEB-EPD logic not present, 1 => SEB-EPD logic present
EPD_DIAGNOSTIC_PRESENT 5 r 0 0 => EPD diagnostic block not present, 1 => EPD diagnostic block present. Encoder Product Detect Diagnostics. Previously called smb_diags
EVENT_LOGGER_PRESENT 6 r 0 0 => Event Logger block not present, 1 => Event Logger block present
DELAY_EQUALIZATION_ENABLE 7 r 0 0 => No support for delay equalization, 1 => Support for delay equalization
TOF_COMP_ENABLE 8 r 0 0 => No support for Time-of-Flight compensation, 1 => Support for Time-of-Flight compensation
PIXEL_PITCH_CORR_ENABLE 9 r 0 0 => No support for pixel-pitch correction, 1 => Support for pixel-pitch correction
CSR_FPM_CTRL_7_FPM_INIT_START 0xc 1 w 0 Start the fpm_init procedure
CSR_FPM_CTRL_7_FPM_INIT_DONE 0x10 1 r 0 fpm_init completed flag
CSR_FPM_CTRL_7_SIGNAL_SELECTION 0x14 6 Controls signal selection
FIRE_PULSE_SEL 0 w 0x0 0 => Use External fire pulses, 1 => Use FPM fire pulses
ENC_PD_EMUL_EN 1 w 0x0 0 => Use POF RX, 1 => Use internal enc/PD emulator
SEB_EPD_EN 2 w 0x0 1 => Enable SEB-EPD interface, 0 => Use POF based interface
SEB_EPD_LINKOUT_SEL 3 w 0x0 0 => SEB_EPD_LINK_OUT is driven by the POF-Tx output, 0 => SEB_EPD_LINK_OUT is driven by the Drop-Watch output
PRINT_START_OVERRIDE 5:4 w 0x0 0- => no override. 10 => override to zero (stop print). 11 => override to one (start print). output of FPM and value for pof_tx
CSR_FPM_CTRL_7_POF_RECEIVER_CONTROL 0x18 9 Controls POF receiver
POF_RX_ENABLE 0 w 0x0 0 => Disable POF RX, 1 => Enable POF RX
UART_REGENERATION_BYPASS 1 w 0x0 0 => Use UART Regeneration, 1 => Bypass UART Regeneration
CLEAR_MAX 2 w 0x0 0 => Disabled, 1 => Load the current value of Absolute Position as new maximum
CLEAR_MIN 3 w 0x0 0 => Disabled, 1 => Load the current value of Absolute Position as new miniumum
UART_RX_DIV 7:4 w 0x4 Defines the number of 200 MHz clock cycles per UART data bit
POF_PROTOCOL_VERSION 8 w 0 0 => Support POF protocol version 0, 1 => Support POF protocol version 1 (allows print_start message)
CSR_FPM_CTRL_7_MONITORING_POINT_SELECTION 0x1c 16 Selects monitoring points for external header
MP0 3:0 w 0x0 Selects first monitoring point
MP1 7:4 w 0x0 Selects second monitoring point
MP2 11:8 w 0x0 Selects third monitoring point
MP3 15:12 w 0x0 Selects fourth monitoring point
CSR_FPM_CTRL_7_COARSE_TIME_INIT 0x20 32 w 0x00000000 Defines coarse time counter value
CSR_FPM_CTRL_7_FINE_TIME_INIT 0x24 29 Fine time counter value/Load counter enable
FINE_TIME_INIT 27:0 w 0x0000000 Defines fine time counter value
TIME_LOAD_EN 28 w 0x0 Writting 1 loads the coarse and fine time counters
CSR_FPM_CTRL_7_FINE_TIME_STATUS 0x28 28 r 0x0000000 Current fine time counter value
CSR_FPM_CTRL_7_COARSE_TIME_STATUS 0x2c 32 r 0x00000000 Current coarse time counter value
CSR_FPM_CTRL_7_POF_RX_STATUS 0x30 32 Status of POF receiver
PARITY_BIT_ERROR_COUNT 15:0 r 0x0000 Counts number of parity errors
SKIPPED_POSITION_ERROR_COUNT 31:16 r 0x0000 Counts position skipped type errors
CSR_FPM_CTRL_7_POF_RX_CONTROL_W 0x34 10 POF receiver error control
ERROR_RATE_THRES 7:0 w 0x0A Defines RX error rate threshold
RX_WATCHDOG_EN 8 w 0x1 0 => Disable RX watchdog, 1 => Enable RX Watchdog
RX_WATCHDOG_CLR 9 w 0x0 0 => RX watchdog counter running, 1 => Clear RX watchdog counter
CSR_FPM_CTRL_7_POF_RX_CONTROL_R 0x38 3 POF receiver error status
RX_WATCHDOG 0 r 0x0 0 => RX watchdog not triggered, 1 => RX watchdog triggered
RX_ERROR_FLAG 1 r 0x0 0 => Error rate below threshold, 1 => Error rate above threshold
PRINT_START_RECEIVED 2 r 0x0 print_start as received over pof. (for protocol zero, will be fixed at '1')
CSR_FPM_CTRL_7_FPM_INTERRUPT 0x3c 12 Interrupt control
IRQ_EN 0 w 0x0 0 => Disable IRQ, 1 => Enable IRQ
RESERVED1 3:1 rsv 0 Reserved
IRQ_CLR 4 w 0x0 0 => Don't clear pending IRQ, 1 => Clear pending IRQ
RESERVED2 7:5 rsv 0 Reserved
IRQ_MASK 8 w 0x0 0 => IRQ not masked, 1 => IRQ masked
RESERVED3 11:9 rsv 0 Reserved
CSR_FPM_CTRL_7_IRQ_STATUS 0x40 1 r 0x0 0 => IRQ not active, 1 => IRQ active
CSR_FPM_CTRL_7_PD_CNT 0x44 16 r 0x0 PD count, at the Pulse-Generator input
CSR_FPM_CTRL_7_DROP_WATCH_CONFIG 0x48 32 Drop-Watch configuration
DW_SRC 3:0 w 0x0 Select the source channel for the drop-watch
RESERVED 15:4 rsv 0 Reserved
DW_PULSE_WIDTH 31:16 w 0x000A Drop-Watch pulse width, expressed as clock cycles @100MHz
CSR_FPM_CTRL_7_SEB_EPD_LED_STATUS 0x4c 12 SEB-EPD LED status
LED_PD_G 0 r 0x0 LED PD Green
LED_PD_Y 1 r 0x0 LED PD Yellow
LED_PD_R 2 r 0x0 LED PD Red
LED_ENC_P1_G 3 r 0x0 LED Encoder-Phase-1 Green
LED_ENC_P1_Y 4 r 0x0 LED Encoder-Phase-1 Yellow
LED_ENC_P1_R 5 r 0x0 LED Encoder-Phase-1 Red
LED_ENC_P2_G 6 r 0x0 LED Encoder-Phase-2 Green
LED_ENC_P2_Y 7 r 0x0 LED Encoder-Phase-2 Yellow
LED_ENC_P2_R 8 r 0x0 LED Encoder-Phase-2 Red
LED_POF_IN_G 9 r 0x0 LED POF-In Green
LED_POF_IN_Y 10 r 0x0 LED POF-In Yellow
LED_POF_IN_R 11 r 0x0 LED POF-In Red

Register/field type key:

TypeDescription
cConstant, with value defined by "reset" attribute
rsvSame as constant, except no reset value and always 0. Can be mixed with write types.
wWrite register (and read—no write only type). Register defined in register block and reset to "reset" attribute value. Split into fields (if applicable) for signalling and output, where attribute associated with fields, not register.
wpWrite with pulse. Register is not declared in block, but write bus split into fields as output port signals, and a pulse generated on write to register address. Register reads back 0. The "reset" attribute is for documentation only, as set externally.
w0Same as w, but auto-clears to 0 (and thus always reads as 0). At output port, signal will go high for one cycle when bit is written with a 1 (no effect if written to a 0). No "reset" attribute, as must always be 0.
rRead only value. Input ports generated for each field (where applicable), and concatenated on returned read data bus.
rpSimilar to r, but a pulse generated on a read access to the register address to allow peripheral logic to update value. The "reset" attribute is for documentation only, as set externally.
rwpSimilar to wp, but also generates a (separate) pulse on a read access to the register
bitdefDefines the bits used in the read, set, clear registers
  
SubypeDescription
unsignedRegister/field is specified as an unsigned value.
signedRegister/field is specified as a signed value.
<blank>Register/field sign status is not explicitly defined and defaults to unsigned.

Usage Notes

This is the control registers for the Fire Pulse Manager. this link. The Fire Pulse Manager produces fire-request strobe signals to trigger the print_units to load and fire the printhead (or sub-head). It does so based on either received UART messages over Plastic Optic Fibre (POF) if using the SEB-PDW, or from encoder/PD inputs if using the SEB-EPD. Full details on confluence at this link

 


Copyright © 2024 Global Inkjet Systems. Generated by gen_htm.py —2024-10-30 09:43