| data_streamer_mini_0 | This block is the data streamer part of the print streamer | ||||||
|---|---|---|---|---|---|---|---|
| Register Name | Byte Addr Offset | Field | Bits | Type | subtype | Reset | Description |
| CSR_DATA_STREAMER_MINI_0_IP_ID | 0x0 | 32 | Unique ID for this IP block | ||||
| IP_NUMBER | 7:0 | c | 0x30 | IP identifier number - Data Streamer Mini | |||
| MFR_NUMBER | 15:8 | c | 0x00 | Manufacturer number - GIS | |||
| RESERVED | 31:16 | rsv | 0 | Reserved bits | |||
| CSR_DATA_STREAMER_MINI_0_IP_VER | 0x4 | 32 | Bits[7:0] = Minor version number, Bits[15:8] = Major version number, etc. | ||||
| MINOR_NUMBER | 7:0 | c | 0x01 | Minor number | |||
| MAJOR_NUMBER | 15:8 | c | 0x00 | Major number | |||
| RESERVED | 31:16 | rsv | 0 | Reserved bits | |||
| CSR_DATA_STREAMER_MINI_0_CONTROL | 0x8 | 6 | Control | ||||
| CLEAR_CMD | 0 | w0 | 0 | Clear the command queue of all commands | |||
| CLEAR_ERRORS | 1 | w0 | 0 | Clear outstanding errors. | |||
| DISABLE | 2 | w | 0 | Disable print streamer | |||
| UPDATE_PROGRESS | 3 | w0 | 0 | Write 1 to update the progress registers | |||
| RESET_LOW_WATER | 4 | w0 | 0 | Clear minimum FIFO queue | |||
| CLR_TOTAL_COUNT | 5 | w0 | 0 | Clear total counter | |||
| CSR_DATA_STREAMER_MINI_0_STATUS | 0xc | 14 | Command port | ||||
| QUEUE_SPACE | 11:0 | r | 0 | Amount of space left in queue. Address only commands take 1. New length or New loop Count take 2 | |||
| CMD_ACTIVE | 12 | r | 0 | Busy executing command | |||
| CMD_QUEUE_EMPTY | 13 | r | 0 | Set if the command queue FIFO is empty | |||
| CSR_DATA_STREAMER_MINI_0_CMD_PORT | 0x10 | 32 | Command port. A write adds a command to the command queue. Command is command code followed by parameter word. | ||||
| HANDLE_ID | 7:0 | w | 0 | Operation handle/id | |||
| START_IMAGE | 8 | w | 0 | First data word of this command is Start of Image | |||
| START_LOOP | 9 | w | 0 | Loop Count/Extra Copies start point | |||
| END_IMAGE | 10 | w | 0 | Last data word of this command is last of image. Also end of loop marker | |||
| NEW_LENGTH | 11 | w | 0 | Length has changed. Take notice of new length in cmd_port_length reg | |||
| ADDRESS | 30:12 | wp | 0 | DMA address bits 30..12. Bits 11..0 ignored as all zeroes due to 4K alignment rule | |||
| RSVD1 | 31 | rsv | 0 | Spare | |||
| CSR_DATA_STREAMER_MINI_0_CMD_PORT_LENGTH | 0x14 | 27 | w | 0 | Length of Print Data in DWORD for this command | ||
| CSR_DATA_STREAMER_MINI_0_CMD_PORT_LOOP_COUNT | 0x18 | 12 | w | 0 | Number of loops/Extra copies to do | ||
| CSR_DATA_STREAMER_MINI_0_STAT_SNAP_1 | 0x1c | 20 | Loop count/Extra copies for this command. Must set update_progress bit to get latest value | ||||
| HANDLE | 7:0 | r | 0 | Current handle/id being executed. Must set update_progress bit to get latest value | |||
| LOOP_COUNT | 19:8 | r | 0 | If loop count is active - shows number of loops remaining. If no loop active - 0. Must set update_progress bit to get latest value | |||
| CSR_DATA_STREAMER_MINI_0_STAT_SNAP_DWORD_COUNT | 0x20 | 32 | r | 0 | DWORDS transfered for this image (resets when looping). May span multiple commands. Must set update_progress bit to get latest value | ||
| CSR_DATA_STREAMER_MINI_0_TOTAL_WORD_COUNT | 0x24 | 32 | r | 0 | Total DWord count sent to destination since reset | ||
| CSR_DATA_STREAMER_MINI_0_LOGGER_WR_PTR | 0x38 | 8 | r | 0 | Command port | ||
| CSR_DATA_STREAMER_MINI_0_DIAG_LOGGER_RDATA | 0x3c | 32 | r | 0 | Data streamer command queue logger read data | ||
Register/field type key:
| Type | Description |
|---|---|
| c | Constant, with value defined by "reset" attribute |
| rsv | Same as constant, except no reset value and always 0. Can be mixed with write types. |
| w | Write register (and read—no write only type). Register defined in register block and reset to "reset" attribute value. Split into fields (if applicable) for signalling and output, where attribute associated with fields, not register. |
| wp | Write with pulse. Register is not declared in block, but write bus split into fields as output port signals, and a pulse generated on write to register address. Register reads back 0. The "reset" attribute is for documentation only, as set externally. |
| w0 | Same as w, but auto-clears to 0 (and thus always reads as 0). At output port, signal will go high for one cycle when bit is written with a 1 (no effect if written to a 0). No "reset" attribute, as must always be 0. |
| r | Read only value. Input ports generated for each field (where applicable), and concatenated on returned read data bus. |
| rp | Similar to r, but a pulse generated on a read access to the register address to allow peripheral logic to update value. The "reset" attribute is for documentation only, as set externally. |
| rwp | Similar to wp, but also generates a (separate) pulse on a read access to the register |
| bitdef | Defines the bits used in the read, set, clear registers |
| Subype | Description |
| unsigned | Register/field is specified as an unsigned value. |
| signed | Register/field is specified as a signed value. |
| <blank> | Register/field sign status is not explicitly defined and defaults to unsigned. |
See this link
Copyright © 2024 Global Inkjet Systems. Generated by gen_htm.py —2024-9-15 17:15