host: examples: bladeRF-cli: Added sync_trx example
This example demonstrates how to use the bladeRF-cli to perform synchronized sampling using two devices and a trigger signal on J71-4.
This commit is contained in:
parent
6810cf6223
commit
d3bc3dc27f
7 changed files with 269 additions and 0 deletions
2
host/examples/bladeRF-cli/sync_trx/.gitignore
vendored
Normal file
2
host/examples/bladeRF-cli/sync_trx/.gitignore
vendored
Normal file
|
|
@ -0,0 +1,2 @@
|
|||
*.csv
|
||||
*.bin
|
||||
142
host/examples/bladeRF-cli/sync_trx/README.md
Normal file
142
host/examples/bladeRF-cli/sync_trx/README.md
Normal file
|
|
@ -0,0 +1,142 @@
|
|||
# Synchronized TRX #
|
||||
|
||||
This example illustrates how to synchronize RX and TX sampling on
|
||||
multiple devices, using the bladeRF-cli and the trigger functionality
|
||||
introduced in FPGA v0.6.0.
|
||||
|
||||
This example assumes the use of an RF power splitter/combiner and two bladeRF
|
||||
devices, connected as follows:
|
||||
|
||||
1. The "master" bladeRF has both its TX and RX ports connected to
|
||||
the combiner.
|
||||
|
||||
2. The "slave" bladeRF has its RX port connected to the combiner.
|
||||
|
||||
3. Pin 4 on J71 on both devices is connected together. This connects
|
||||
the trigger signal on both devices. The "master" will output this
|
||||
signal, and the "slave" will receive it.
|
||||
|
||||
4. Pin 2 on J71 on both devices is connected. This provides a common ground.
|
||||
|
||||
5. The J62 SMB clock connector of both devices are connected together.
|
||||
The "master" bladeRF will output its 38.4 MHz reference clock, and the
|
||||
"slave" bladeRF will utilize this reference instead of its own on-board
|
||||
clock. This ensures that both devices are sampling using the same clock.
|
||||
|
||||
When a trigger is "armed," the FPGA will gate both transmit and receive
|
||||
samples; the flow of samples to/from the host is blocked. The assertion
|
||||
("firing") of the trigger signal unblocks samples, causing all devices to
|
||||
begin transmitting or receiving within +/- 1 sample clock period.
|
||||
|
||||
In this example, the "master" will transmit a series of on-off pulses at a
|
||||
1 MHz offset, and both the "master" and "slave" will receive these pulses. The
|
||||
transmission and reception are synchronized using the J71-4 trigger signal.
|
||||
|
||||
## Creating Samples ##
|
||||
|
||||
Scripts are provided to create a samples.csv file containing a single pulse.
|
||||
This files consists of 1,000 zeros, followed by 100 samples of a CW tone,
|
||||
followed by 1,000 more zeros.
|
||||
|
||||
In Linux and OSX, run `create_samples.sh`. In Windows, run `create_samples.bat`.
|
||||
This script make take a few moments to complete.
|
||||
|
||||
## Executing the Example Scripts ##
|
||||
|
||||
Two bladeRF-cli scripts, `master.txt` and `slave.txt`, are provided for this
|
||||
example.
|
||||
|
||||
The `master.txt` script configures the "master" device to output its
|
||||
reference clock on the SMB connector (J62), arm a TX "master" trigger, and
|
||||
arm an RX "slave" trigger.
|
||||
|
||||
Note that even though both the RX and TX paths are on the same device, one
|
||||
of these must assume the "master" trigger role that will output the trigger signal.
|
||||
Internally, the other path with receive this -- it is *very* important
|
||||
that both not be configured as "master", as this would cause contention
|
||||
over the trigger signal.
|
||||
|
||||
In a multi-device configuration, especially for this master-slave setup, it is
|
||||
recommended to run the bladeRF-cli in a manner that specifies the device
|
||||
to open via serial number.
|
||||
|
||||
Run `bladeRF-cli -p` to see a list of available devices. For example:
|
||||
|
||||
```
|
||||
$ bladeRF-cli -p
|
||||
|
||||
Backend: libusb
|
||||
Serial: e93f190c76e987cd7f462026f965a1a1
|
||||
USB Bus: 1
|
||||
USB Address: 13
|
||||
|
||||
Backend: libusb
|
||||
Serial: b74ed347390d35c29923e80f64c9d904
|
||||
USB Bus: 12
|
||||
USB Address: 8
|
||||
|
||||
```
|
||||
|
||||
For this example, the "master" is the device with serial number `b57...`
|
||||
and the "slave" is the device with serial number `e93...`.
|
||||
|
||||
In one terminal, run the `master.txt` script:
|
||||
|
||||
```
|
||||
$ bladeRF -d '*:serial=b74' -s master.txt -i
|
||||
```
|
||||
|
||||
In another terminal, run the `slave.txt` script:
|
||||
|
||||
```
|
||||
$ bladeRF -d '*:serial=e93' -s slave.txt
|
||||
```
|
||||
|
||||
At this point, both devices' sample streams are blocked and awaiting
|
||||
a trigger. In the "master" console, fire the trigger via:
|
||||
|
||||
```
|
||||
trigger j71-4 tx fire
|
||||
```
|
||||
|
||||
Wait for the RX and TX operations complete via the commands:
|
||||
|
||||
```
|
||||
rx wait; tx wait
|
||||
```
|
||||
|
||||
It will most likely be the case that these operations have finished
|
||||
before you can type these commands. They will return immediately if
|
||||
this is true.
|
||||
|
||||
## Viewing the Results ##
|
||||
|
||||
The results may be viewed using [Octave] [1] or [MATLAB] [2].
|
||||
|
||||
Run one of these programs in this directory and execute the
|
||||
`plot_samples` function provided in this directory. This script
|
||||
will load and plot samples from the `master_tx.csv`, `master_rx.csv`, and
|
||||
`slave_rx.csv` files located in the current working directory.
|
||||
|
||||
Note that in the resulting plot, the first pulse transmitted by the "master"
|
||||
will be red/orange. The signal received by the "master" device is blue. The
|
||||
signal received by the "slave" device is green.
|
||||
|
||||
Zoom in to see the first few pulses in detail. The reception of the pulse by
|
||||
the "master" and "slave" devices should be synchronized within +/- 1 samples.
|
||||
|
||||
Although the devices' sampling clocks are synchronized, they are not guaranteed
|
||||
to be phase-aligned; the mixers in each device operate using independent
|
||||
PLLs. However, the phase offset between the synchronized devices should remain
|
||||
fixed. This allows for opportunities to determine and compensate for
|
||||
phase offsets.
|
||||
|
||||
Lastly, there is a fixed offset between the transmission of the signal
|
||||
by the "master" device, and its reception. This length of this offset
|
||||
is determined by the TX chain in the FPGA and LMS6002D, and should remain
|
||||
a constant value. Thus, one can make a priori assumptions about this value
|
||||
after quantifying it for a particular FPGA version. (Changes to the FPGA
|
||||
code could alter this value.)
|
||||
|
||||
[1]: https://www.gnu.org/software/octave/ "GNU Octave"
|
||||
[2]: https://www.mathworks.com/products/matlab "MATLAB"
|
||||
9
host/examples/bladeRF-cli/sync_trx/create_samples.bat
Normal file
9
host/examples/bladeRF-cli/sync_trx/create_samples.bat
Normal file
|
|
@ -0,0 +1,9 @@
|
|||
@echo off
|
||||
|
||||
set OUTFILE=master_tx.csv
|
||||
if exist %OUTFILE% del %OUTFILE%
|
||||
|
||||
echo Creating %OUTFILE%. This window will close when this is done.
|
||||
for /L %%G in (1, 1, 1000) do echo "0, 0" >> %OUTFILE%
|
||||
for /L %%G in (1, 1, 100) do echo "1447, 1447" >> %OUTFILE%
|
||||
for /L %%G in (1, 1, 1000) do echo "0, 0" >> %OUTFILE%
|
||||
29
host/examples/bladeRF-cli/sync_trx/create_samples.sh
Executable file
29
host/examples/bladeRF-cli/sync_trx/create_samples.sh
Executable file
|
|
@ -0,0 +1,29 @@
|
|||
#!/bin/sh
|
||||
#
|
||||
# Creates a master_tx.csv file
|
||||
################################################################################
|
||||
|
||||
OUTFILE=master_tx.csv
|
||||
|
||||
rm -f ${OUTFILE}
|
||||
|
||||
# Write zeros
|
||||
i=0
|
||||
while [ $i -lt 1000 ]; do
|
||||
echo "0, 0" >> ${OUTFILE}
|
||||
i=$(expr $i + 1)
|
||||
done
|
||||
|
||||
# Write a pulse (i = q = sqrt(2)/2)
|
||||
i=0
|
||||
while [ $i -lt 100 ]; do
|
||||
echo "1447, 1447" >> ${OUTFILE}
|
||||
i=$(expr $i + 1)
|
||||
done
|
||||
|
||||
# Write zeros
|
||||
i=0
|
||||
while [ $i -lt 1000 ]; do
|
||||
echo "0, 0" >> ${OUTFILE}
|
||||
i=$(expr $i + 1)
|
||||
done
|
||||
32
host/examples/bladeRF-cli/sync_trx/master.txt
Normal file
32
host/examples/bladeRF-cli/sync_trx/master.txt
Normal file
|
|
@ -0,0 +1,32 @@
|
|||
# Set up device parameters
|
||||
set frequency rx 922M
|
||||
set frequency tx 923M
|
||||
set samplerate 6M
|
||||
set bandwidth 3M
|
||||
set txvga1 -15
|
||||
set txvga2 0
|
||||
set lnagain 6
|
||||
set rxvga1 10
|
||||
set rxvga2 0
|
||||
|
||||
# Configure TX & RX operations
|
||||
tx config file=master_tx.csv format=csv repeat=25 timeout=60s
|
||||
rx config file=master_rx.csv format=csv n=60000 timeout=60s
|
||||
|
||||
# Output reference clock
|
||||
set smb_mode output
|
||||
|
||||
# Arm the triggers
|
||||
trigger j71-4 tx master
|
||||
trigger j71-4 rx slave
|
||||
|
||||
# Start streaming sampling
|
||||
rx start
|
||||
tx start
|
||||
|
||||
# Inform user how to fire trigger
|
||||
echo " ---------------------------------------------------------------"
|
||||
echo " Run the slave.txt script in another terminal."
|
||||
echo " Then, run 'trigger j71-4 tx fire' to fire trigger."
|
||||
echo " ---------------------------------------------------------------"
|
||||
echo ""
|
||||
25
host/examples/bladeRF-cli/sync_trx/plot_samples.m
Normal file
25
host/examples/bladeRF-cli/sync_trx/plot_samples.m
Normal file
|
|
@ -0,0 +1,25 @@
|
|||
% This script assumes it is being run from:
|
||||
% ${BLADERF}/host/examples/bladeRF-cli/sync_trx
|
||||
%
|
||||
% If this is not the case, change the following addpath() line to point to:
|
||||
% ${BLADERF}/host/misc/matlab
|
||||
%
|
||||
% This directory contains the load_csv() function.
|
||||
addpath('../../../misc/matlab')
|
||||
|
||||
master_tx = load_csv('master_tx.csv');
|
||||
master_rx = load_csv('master_rx.csv');
|
||||
slave_rx = load_csv('slave_rx.csv');
|
||||
|
||||
master_tx_len = length(master_tx);
|
||||
master_rx_len = length(master_rx);
|
||||
slave_rx_len = length(slave_rx);
|
||||
|
||||
% Scale the master_tx samples to the max RX'd amplitude
|
||||
% just to make the plot a bit easier to read.
|
||||
abs_master_tx = abs(master_tx) * max(abs(master_rx));
|
||||
|
||||
plot(1:master_tx_len, abs_master_tx, 'r', ...
|
||||
1:master_rx_len, abs(master_rx), 'g', ...
|
||||
1:slave_rx_len, abs(slave_rx), 'b');
|
||||
|
||||
30
host/examples/bladeRF-cli/sync_trx/slave.txt
Normal file
30
host/examples/bladeRF-cli/sync_trx/slave.txt
Normal file
|
|
@ -0,0 +1,30 @@
|
|||
# Set up device parameters
|
||||
set frequency rx 922M
|
||||
set frequency tx 922M
|
||||
set samplerate 6M
|
||||
set bandwidth 3M
|
||||
set lnagain 6
|
||||
set rxvga1 10
|
||||
set rxvga2 0
|
||||
|
||||
# Configure RX & TX operations
|
||||
rx config file=slave_rx.csv format=csv n=60000 timeout=60s
|
||||
|
||||
# Use reference clock input from master.
|
||||
# This assumes the master is already outputting this reference.
|
||||
set smb_mode input
|
||||
|
||||
# Arm the trigger
|
||||
trigger j71-4 rx slave
|
||||
|
||||
# Start streaming sampling
|
||||
rx start
|
||||
|
||||
# Inform user how to fire trigger
|
||||
echo " ---------------------------------------------------------------"
|
||||
echo " Ready. Fire the trigger on the master device."
|
||||
echo " ---------------------------------------------------------------"
|
||||
|
||||
# Wait for the RX to complete and then finish up.
|
||||
rx wait
|
||||
|
||||
Loading…